COMPARATIVE STUDY OF ULTRASOUND-ASSISTED EXTRACTION OF ANTIOXIDANT COMPOUNDS FROM AVOCADO WASTE WITH AND WITHOUT RECIRCULATION

Vol.2, 2025 - 331276
Póster
Favoritar este trabajo
¿Cómo citar este artículo?
Resúmenes

Ultrasound-assisted extraction (UAE) is a alternative to conventional techniques demonstrating high efficacy in extracting antioxidants. The main types of ultrasound currently used are ultrasonic probes and ultrasonic baths, and there is limited information in the literature on recirculation systems. Avocado oil offers health benefits due to its nutritional composition. The residues generated by the avocado oil processing industry contain antioxidant compounds that can be exploited industrially. Thus, this study aimed to compare the extraction processes of antioxidant compounds from the residue of avocado oil production, in ultrasound systems with and without recirculation. UAE was performed using a UIP1000hdT (Hielscher, Germany), with an 18 mm (diameter) probe and a power of 200 W. Open (no recirculation) and closed (recirculation of the residue and the extractant solution) systems were compared. The solid:liquid ratio was 1:20, employing a 50% hydroethanolic solution. Extraction kinetics were conducted in the non-circulation system (up to 24 minutes) and with circulation (up to 180 minutes). The extracts were filtered and analyzed for total phenolic content and antioxidant capacity by ABTS+ and DPPH methods. In both systems, the kinetics indicated a pronounced increase in total phenolics up to 15 minutes of extraction, followed by a less pronounced rise. The phenolic contents present in the extracts after 15 minutes of extraction were 1019.59 mg gallic acid equivalent/100g of residue for the open system and 1056.09 mg gallic acid equivalent/100g of residue for the closed system. For antioxidant capacity after 15 minutes of extraction, the values were 70.43 µM Trolox/g (ABTS+) and 18.93 µM Trolox/g (DPPH) of residue for the open system, and 37.31 µM Trolox/g (ABTS+) and 19.90 µM Trolox/g (DPPH) of residue for the closed system. However, increasing the extraction time beyond 15 minutes raised energy costs and potentially volatilized the solvent in the open system. In the non-circulation system, the 15 minute treatment did not differ significantly from the 180 minute circulation treatment, with values of 1059.09 and 1082.99 mg/100 g, respectively, indicating that longer times do not provide substantial gains in extraction. Thus, the best UAE condition for antioxidant compounds in avocado residue, under these conditions, was 15 minutes. The main phenolic compounds identified in these extracts were epicatechin, clorogenic acid and quercetin. For industrial scale, the circulating system allows processing larger sample volumes and easier temperature control, while the non-circulation requires more effort for temperature control and sample homogeneity, and does not enable large-volume extraction.

¡Comparte tus ideas o preguntas con los autores!

¿Sabías que el mayor estímulo en el desarrollo científico y cultural es la curiosidad? ¡Deje sus preguntas o sugerencias al autor!

Inicia sesión para interactuar

¿Tiene alguna pregunta o sugerencia? ¡Comparte tus comentarios con los autores!

Instituciones
  • 1 Universidade Federal do Rio de Janeiro, UFRJ
  • 2 Universidade Federal Rural do Rio de Janeiro
  • 3 Embrapa
  • 4 Embrapa agroindústria de alimentos
Eje Temático
  • Ingeniería de procesos y tecnologías emergentes
Palabras Clave
Avocado
Antioxidants
Ultrasound