To cite this paper use one of the standards below:
Ultrasound-assisted extraction (UAE) is a alternative to conventional techniques demonstrating high efficacy in extracting antioxidants. The main types of ultrasound currently used are ultrasonic probes and ultrasonic baths, and there is limited information in the literature on recirculation systems. Avocado oil offers health benefits due to its nutritional composition. The residues generated by the avocado oil processing industry contain antioxidant compounds that can be exploited industrially. Thus, this study aimed to compare the extraction processes of antioxidant compounds from the residue of avocado oil production, in ultrasound systems with and without recirculation. UAE was performed using a UIP1000hdT (Hielscher, Germany), with an 18 mm (diameter) probe and a power of 200 W. Open (no recirculation) and closed (recirculation of the residue and the extractant solution) systems were compared. The solid:liquid ratio was 1:20, employing a 50% hydroethanolic solution. Extraction kinetics were conducted in the non-circulation system (up to 24 minutes) and with circulation (up to 180 minutes). The extracts were filtered and analyzed for total phenolic content and antioxidant capacity by ABTS+ and DPPH methods. In both systems, the kinetics indicated a pronounced increase in total phenolics up to 15 minutes of extraction, followed by a less pronounced rise. The phenolic contents present in the extracts after 15 minutes of extraction were 1019.59 mg gallic acid equivalent/100g of residue for the open system and 1056.09 mg gallic acid equivalent/100g of residue for the closed system. For antioxidant capacity after 15 minutes of extraction, the values were 70.43 µM Trolox/g (ABTS+) and 18.93 µM Trolox/g (DPPH) of residue for the open system, and 37.31 µM Trolox/g (ABTS+) and 19.90 µM Trolox/g (DPPH) of residue for the closed system. However, increasing the extraction time beyond 15 minutes raised energy costs and potentially volatilized the solvent in the open system. In the non-circulation system, the 15 minute treatment did not differ significantly from the 180 minute circulation treatment, with values of 1059.09 and 1082.99 mg/100 g, respectively, indicating that longer times do not provide substantial gains in extraction. Thus, the best UAE condition for antioxidant compounds in avocado residue, under these conditions, was 15 minutes. The main phenolic compounds identified in these extracts were epicatechin, clorogenic acid and quercetin. For industrial scale, the circulating system allows processing larger sample volumes and easier temperature control, while the non-circulation requires more effort for temperature control and sample homogeneity, and does not enable large-volume extraction.
Visualizaciones por mes
Conteo de Galoá, excluyendo robots conocidos. Actualizado el 22/11/2026.
Visualizaciones por mes
Conteo de Galoá, excluyendo robots conocidos. Actualizado el 22/11/2026.
Con casi 200.000 artículos publicados, Galoá permite a los académicos compartir y descubrir investigaciones de vanguardia a través de nuestra plataforma de publicación académica optimizada y accesible.
Obtenga más información sobre nuestros productos:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Atención: este no es un DOI para el trabajo y, como tal, no se puede usar en Lattes para identificar un trabajo en particular.
Check the link "How to cite" en la página del papel, para ver cómo citar correctamente el papel