The high consumption of sugars has been identified as the main contributor to obesity, a significant risk factor for type II diabetes mellitus. As a result, the industry has intensely promoted sweeteners in low- or no-calorie foods as an important class of products to control body weight and diabetes. According to data from Expert Market Research (2021), the market value of these compounds reached almost US$ 6.37 billion in 2020, and the forecast is to reach an estimated value of US$ 8.24 billion in 2026. When subjected to high temperatures, sweeteners can decompose into unwanted products. Thermal analysis techniques have been successfully employed in the characterization of food additives and are well described for the study of thermal stability and decomposition mechanisms. Thus, this study aims to investigate the content of natural and artificial sweeteners in commercial samples of tabletop sweeteners using thermal analysis and FTIR techniques. Three samples of artificial sweeteners (A1, C1, U1) and three samples of natural sweeteners (E2, E3, M1) were analyzed. The thermal analysis techniques (TG, DTG and DTA) were performed in the temperature range from 25 to 800ºC, under an inert atmosphere. The thermal analysis results suggested that the dextrose content in samples A1, C1 and U1 was higher than the artificial sweeteners (aspartame, saccharin, sucralose, respectively), which these samples are based. Samples M1 and E2 had similar thermal profiles, and the results suggested that both had higher erythritol content than the natural sweeteners (Stevia rebaudiana and Monk fruit extracts, respectively) present. The FTIR spectra showed absorption bands of these compounds, confirming their presence in the samples. The FTIR spectra of all samples showed O-H stretch bands at 3440 to 3320cm-1, and C-H stretch bands at 2970 to 2883cm-1. Sample A1 also showed deformation band of the N-H bond at 1547cm-1.

Questões (1 tópico)

Compartilhe suas ideias ou dúvidas com os autores!

Sabia que o maior estímulo no desenvolvimento científico e cultural é a curiosidade? Deixe seus questionamentos ou sugestões para o autor!

Faça login para interagir

Tem uma dúvida ou sugestão? Compartilhe seu feedback com os autores!

Autor

Michelle Gonçalves Mothé

Muito obrigada pelo elogio, Crislei!

Nós acreditamos na potencialidade das técnicas de caracterização, como a análise térmica, para controle de qualidade dos alimentos, o que ainda tem sido pouco explorada. Forte abraço.