Energy and Power in ultrasound system (probe) to inactive microorganism in food matrix
The effect of ultrasound on properties or characteristics in food matrix has been studied in last years by different researchers. The objective of this study was to describe the relationship between the energy released (Joules) in the medium by ultrasound probe, and the power dissipated (W/cm3), against microbial reduction in a matrix food. Were sonicated distilled water (Cp 4.186 Jg-1 °C-1) and a non-homogeneous food matrix (ρ: 1.230 g/cm3, 12% (w/w) protein, Cp: 2.992 Jg-1 ° C -1). Qsonica probe was used, Q Sonicator Model 700 watts at 20 kHz with amplitude tip of 320μm and 1.6 mm in diameter in two amplitudes (96-192 µm) with pulses in seconds (30on and 20on-30off-20off) for 10 minutes. The power dissipated was calculated and determined the reduction in total viable counts (mesophiles) in three independent assays with three replicates. Linear effect was observed between the energy released and the calculated power regardless of the nature of the matrix. Microbial results showed a reduction 1.8 log cfu mL-1 in five minutes of treatment to 829 Joules of energy and power 1,328. W/cm3