This study evaluated the effectiveness of benchtop nuclear magnetic resonance (TD-NMR) in detecting adulteration of green coffee oil (GCO) with sunflower oil, aiming to develop a fast, accurate, affordable, and low-cost methodology without the use of solvents or complex sample preparation. Mixtures of GCO and sunflower oil in eleven proportions (0–100%, v/v) were analyzed using a SpinLock SLK-200 spectrometer (11 MHz, 30 mm, 30 °C) with a CPMG sequence, extracting the T₂(3) parameter via tri-exponential fitting. Commercial samples (C1–C4) were analyzed following the same protocol. High-resolution 1H NMR spectra were obtained on a Bruker Avance III (600 MHz, 30 °C), and FT-IR analyses were performed on a Bruker Vertex 70. TD-NMR and FT-IR data were processed in OriginLab 9.0, and HR-NMR data were processed in TopSpin.
The CPMG curves showed that higher GCO contents accelerate relaxation, reducing T₂ values due to lower molecular mobility. Data processing revealed three components (T₂(1), T₂(2), and T₂(3)), with the latter being the most sensitive to compositional variation. T₂(3) showed a strong negative correlation with GCO content (R² = 0.97587), confirming the feasibility of the method for adulteration detection. In the commercial samples, C2 and C4 exhibited relaxation profiles consistent with pure GCO, whereas C1 and C3 displayed higher T₂(3) values, suggesting adulteration. High-resolution NMR detected the cafestol and kahweol markers only in C2 and C4, confirming the absence of GCO in the other samples. FT-IR results supported this observation, showing characteristic GCO bands (~1502 and ~1567 cm⁻¹) only in the non-adulterated samples.
In conclusion, TD-NMR is a rapid and effective screening method for detecting adulteration in GCO, showing good linearity in calibration and requiring minimal sample preparation, with the possibility of analyzing sealed packages. However, for confirmation, the complementary use of more specific techniques such as high-resolution NMR and FT-IR is recommended. The combined application of these methodologies enhances the efficiency of quality control and fraud prevention in the sector.
Views per month
Galoá count, excluding known robots. Updated on 22/11/2026.
Views per month
Galoá count, excluding known robots. Updated on 22/11/2026.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper