Enantioselective analysis of the pesticide prothioconazole and its main metabolite in liver microsomes by coupling aquiral-chiral columns

Favoritar este trabalho
Como citar esse trabalho?
Detalhes
  • Tipo de apresentação: e-Pôster
  • Eixo temático: Química Analítica - ANA
  • Palavras chaves: Enantioseparation; LC-MS/MS; DLLME; Achiral-chiral coupling; Prothioconazole;
  • 1 Departamento de Química / Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto / Universidade de São Paulo
  • 2 Faculdade de Ciências Farmacêuticas de Ribeirão Preto / Universidade de São Paulo

Enantioselective analysis of the pesticide prothioconazole and its main metabolite in liver microsomes by coupling aquiral-chiral columns

Icaro Salgado Perovani

Departamento de Química / Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto / Universidade de São Paulo

Resumo

Pesticide use has been increasing mainly to the increase in world population and food demand. This has been led to increased exposure to these chemicals, resulting in a harmful scenario for humans and wildlife (Carvalho, 2017). Prothioconazole (PTC) is a triazole chiral fungicide that has been found in food samples (Gaweł et al., 2019). In addition, studies in mammals showed that PTC was converted into desthio-prothioconazole (D-PTC) after hepatic metabolism (Zhang et al., 2019). In order to evaluate the metabolism of this pesticide in a human model, the aim of this work was to analyze the pesticide prothioconazole in human liver microsomes after sample preparation optimization and method validation. The enantioseparation of PTC and D-PTC was carried out on a Chiralcel OD-3 column (100 x 4.6 mm, 3 µm) using the mixture of acetonitrile: water 60:40 (v/v) with 0.1% (v/v) formic acid as mobile phase in an LC-MS/MS system. An achiral C18 column (100 x 4.6 mm, 2.7 µm) was coupled before the chiral column to separate PTC and D-PTC. Dispersive liquid-liquid microextraction (DLLME) was used as a sample preparation technique after optimization by using a central composite design. The final condition of the DLLME comprised injecting 100 µL of the mixture butyl acetate: ethanol 1:3 (v/v) into 200 µL of the sample. After that, the sample was centrifuged and 15 µL of the butyl acetate was collected and diluted into 85 µL of ethanol before being injected into the chromatographic system. These conditions yielded an extraction efficiency of 89 and 92% for PTC and D-PTC respectively. The bioanalytical method was fully validated. The PTC method linearity comprised the range 0.0321 – 5.50 µmol L-1, for D-PTC the linear range was 0.0105 – 2.10 µmol L-1. The method was accurate and precise, and the analytes remained stable during the analysis.

Carvalho, F.P., 2017. Food Energy Secur. https://doi.org/10.1002/fes3.108
Gaweł, M., Kiljanek, T., Niewiadowska, A., Semeniuk, S., Goliszek, M., Burek, O., Posyniak, A., 2019. Food Chem. 282, 36–47. https://doi.org/10.1016/j.foodchem.2019.01.003
Zhang, Z., Gao, B., He, Z., Li, L., Shi, H., Wang, M., 2019. Chemosphere 224, 77–84. https://doi.org/10.1016/j.chemosphere.2019.02.119

Compartilhe suas ideias ou dúvidas com os autores!

Sabia que o maior estímulo no desenvolvimento científico e cultural é a curiosidade? Deixe seus questionamentos ou sugestões para o autor!

Faça login para interagir

Tem uma dúvida ou sugestão? Compartilhe seu feedback com os autores!