Para citar este trabalho use um dos padrões abaixo:
Enantioselective in vitro metabolism study of the pesticide diclofop-methyl: optimization of the chiral separation and sample preparation
Maike Felipe Santos Barbetta
Departamento de Química / Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto / Universidade de São Paulo
Agora você poderia compartilhar comigo suas dúvidas, observações e parabenizações
Crie um tópicoDiclofop-methyl (DCM) is a chiral herbicide from the aryloxyphenoxypropionate class, specially applied to wheat and barley cultures against weed. Some works have reported that this pesticide shows an enantioselective degradation in fruit and vegetables [1] and enantioselective metabolism in loach [2]. However, information about its affect in humans is scarcely. In addition, there is no data regarding its metabolism and interaction with cytochrome P450 enzymes from humans. The knowledge of those information are important in order to understand the metabolic profile of this pesticide in humans and to prevent drug-pesticide interactions. The aim of this work was to optimize an enantioselective chromatographic separation and a sample preparation technique to analyze the DCM and its main metabolite, diclofop (DC), in human liver microsomes to be further used in in vitro metabolism studies. In order to reach a suitable resolution of DCM and DC, several chromatographic parameters were evaluated, such as column temperature, flow rate, elution mode (reversed and polar organic), mobile phase composition (water, acetonitrile, methanol and ethanol) and chiral columns (Chiralcel OD-RH®, Chirobiotic TAG®, Chiralpak AD-RH® e AD-3®). Next, to extract the analytes from microsomal medium, liquid-liquid extraction was optimized and the following parameters were evaluated: (i) solvent type (ethyl acetate, chloroform and dichloromethane), (ii) solvent volume (400, 600, 800 and 1000 μL), (iii) extraction agitation time (5, 10 and 15 min). Other parameters were kept constant: stirring speed at 1500 rpm and centrifugation at 1600 xg for 10 min at 4 ºC. The best conditions for enantioseparation were obtained by using the Chiralpak AD-3® column, in which there were two possible conditions: methanol: ethanol with 0.1% of formic acid (80:20 v/v) and ethanol: aqueous solution of formic acid 0.1% v/v (70:30 v/v). Since the first condition was faster (7.5 min) it was chosen and further adapted to HPLC-MS. The final condition was: Chiralpak AD-3® column and 63% methanol: 27% ethanol: 10% water with 0.75% formic acid and 0.25% ammonium acetate was used as mobile phase. The flow rate and column temperature was, respectively, 0.8 mL/min and 30 ºC. The resolution between the peaks was higher than 1.5 and the total run time was 7.5 min. The best extraction condition was accomplished by using 800 μL of ethyl acetate and extraction agitation time of 5 min. By using this condition, the recovery of the analytes was 100% and no interferents were observed either in the retention of DCM or DC.
1 - LU, Y. et al. Chirality v. 28, p. 78–84, 2016.
2 - MA, R. et al. J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. v. 969, p. 132–138, 2014.
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo