Abstract

The vessel in charge of the production, storage and transportation of oil and gas (FPSO), is a type of platform widely used in the offshore industry that, in general, are VLCC (Very Large Crude Carrier) type oil tankers, which receive an oil processing plant on deck, and their systems are suitable to ensure the correct functioning of the oil and gas production and storage process. In the conversion phase many changes and repairs to the plates and stiffeners are included to comply with the regulations of the classifiers, this added to the age of the hull of the converted VLCC, generates constant deficiencies in the hull structure, in most cases because of corrosion.

Therefore, FPSO maintenance requires routine inspections and constant repairs with work carried out 'in situ', with conventional repairs involving hot processes for cutting and welding plates, requiring the use of a time-consuming and costly cleaning procedure of the tanks involved and possibly other adjacent tanks. The use of laminated composite material on these damaged panels, with proper surface preparation, can be a very efficient repair alternative to conventional methods. The main advantages are the simplification of tank cleaning and reduction of fire and explosion risks.

This research will analyze the load capacity of a stiffened side panel located in the middle section of an FPSO, when it is intact, when it is affected by the uniform corrosion of some plates (causing a decrease in plate thickness), and repaired with the application of composite material formed by layers of carbon fiber with a polymer matrix.

The side panel located in the middle section is subjected to hydrostatic pressure and axial compression loads. Therefore, the panel will be evaluated by means of a finite element analysis for applying constant hydrostatic pressure and then compressive axial loading until collapse.

The research seeks the boundary conditions that best represent the behavior of the stiffened panel when it is subjected to lateral pressure, compression forces. Next, the stacking sequence of the layers will be evaluated to obtain the fiber orientations and the thickness of the composite required to recover the load capacity of the stiffened panel when general corrosion reduces the thickness of the sheet by 40%.

Finally, graphs will be shown of the mechanical behavior of the panel in an intact state, corroded by 20% and 40% with the application of composite, thus showing that the repair manages to recover the panel's load capacity, demonstrating the possibility of the unit continuing to operate without compromising its safety.

Share your ideas or questions with the authors!

Did you know that the greatest stimulus in scientific and cultural development is curiosity? Leave your questions or suggestions to the author!

Sign in to interact

Have a question or suggestion? Share your feedback with the authors!

Institutions
  • 1 Universidade Federal do Rio de Janeiro (UFRJ)
Track
  • Integrity management and life extension (including inspection and maintenance)
Keywords
Panel Repair
Finite Elements
Composite materials
Corrosion of plates