High energy efficiency production of reactive nitrogen species in plasma activated water

Favoritar este trabalho
Como citar esse trabalho?
Detalhes
  • Tipo de apresentação: e-Pôster
  • Eixo temático: Físico-Química - FIS
  • Palavras chaves: Energy efficiency; Reactive Nitrogen Species; Plasma activated water;
  • 1 Universidade Tecnológica Federal do Paraná

High energy efficiency production of reactive nitrogen species in plasma activated water

Pericles Inacio Khalaf

Universidade Tecnológica Federal do Paraná

Resumo

In this work, plasma activated water (PAW) containing a large amount of dissolved reactive nitrogen species (RNS) was produced. The cold plasma discharge was generated between a centered high voltage (HV) tungsten pin electrode and the water surface, which acted as the discharge electrode (grounded). A jacketed plasma reactor (200 mL) was filled with 100 mL of ultrapure water. AC high voltage of 60 Hz was applied to the plasma reactor through a HV transformer (NeonEna 17 kV). Ambient air at atmospheric pressure was employed as the plasma gas, and the gas exchange between the reactor and the atmosphere were free trough two cap openings. The waveforms of the voltage and current were measured using a real-time digital oscilloscope (Tektronix TDS 2012C) via a high voltage probe (Caltest CT4028) and a current monitor (Pearson 411). Temperature of the plasma rector jacket was kept constant at 5 oC through a thermostatic circulating bath (Microquimica MQBMP-01). The agitation of the plasma activated water was kept constant at 750 rpm by a magnetic stirrer (NovaInstruments NI 1111). RNS (HNO3 and HNO2) were determined spectrophotometrically (SHIMADZU UV-Vis Spectrophotometer, UV-1800) and their concentrations were calculated trough calibration curves. During the plasma activation time (180 min) samples of PAW were taken for analysis in predetermined time intervals. In the above conditions, the measured average power was 27.1 W, peak-to-peak voltage 7.0 kV and peak-to-peak current 81.3 mA. The energy density (ED, J L-1) was calculated based on the plasma power, treatment time and water volume in order to compare our results to the literature. It was found that the HNO3 concentration increased linearly with the increase of the ED, as HNO3 is a final stable nitrogen specie that accumulates in the medium. HNO2 concentration also increased with the increase of ED, however not linearly. This behavior is explained by the reactivity of HNO2 with reactive oxidant species (ROS) produced in PAW, which decreases HNO2 concentration quickly, especially in acid medium. Energy efficiency (EF) was calculated by the ratio of the observed RNS concentration and applied energy density. The maximum energy efficiency for production of HNO3, HNO2 and their sum (HNO3+HNO2) was 45.8, 34.1 and 62.6 nmol J-1, respectively. In comparison, another work found these values as 9.15, 22.7 and 29.9 nmol J-1, respectively for a RF plasma. In the aforementioned study the plasma discharge was also produced between a high voltage electrode and the water surface, which indicates that the energy efficiency found in the present work is 5.0, 1.5 and 2.1 times greater for HNO3, HNO2 and HNO3+HNO2, respectively for a similar plasma set up.

Compartilhe suas ideias ou dúvidas com os autores!

Sabia que o maior estímulo no desenvolvimento científico e cultural é a curiosidade? Deixe seus questionamentos ou sugestões para o autor!

Faça login para interagir

Tem uma dúvida ou sugestão? Compartilhe seu feedback com os autores!