To cite this paper use one of the standards below:
Synthetic antioxidants are added to several food products to increase shelf life. However, ingestion of tert-butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT) in higher concentrations can provoke adverse effects. This study aimed to extract BHA, BHT, and TBHQ using Disposable Pipette Extraction (DPX) with determination by High-Performance Liquid Chromatography with an Ultraviolet detector (HPLC-UV). The method was adapted from the official method1 for quantifying antioxidants, using a 280 nm wavelength with mobile phases of 5.0% acetic acid in water and 5.0% acetic acid in acetonitrile. The peaks of TBHQ, BHA, and BHT were observed at retention times of 5.2, 13.0, and 18.2 min, respectively. DPX was made using 1.0 mL micropipette tips with silica-based sorbent and a hydrophilic polypropylene frit at the bottom of the SPE cartridge. To increase extraction efficiency, the sorbent type and mass (silica bonded to octyl (C8) or octadecyl (C18)) and the eluent (acetonitrile, methanol, or isopropanol) were optimized. The optimized experimental parameters were as follows: C8 was used as a solid support with a mass of 100 mg, without a washing step, and with volumes of 625, 1000, and 1000 µL for conditioning (acetonitrile), sample, and elution (acetonitrile), respectively. According to the addition-recovery tests, recoveries of 99.17±2.35, 97.40±2.98, and 95.30±4.20% for TBHQ, BHA, and BHT, respectively, were obtained. Analytical curves were developed for each antioxidant, with a linear range from 1.00 to 100 µmol/L, detection (0.28, 0.20, and 0.38 µmol/L for TBHQ, BHA, and BHT) and quantification (0.86, 0.60, and 1.16 µmol/L for TBHQ, BHA, and BHT) limits, repeatability (2.52, 4.06, and 3.78% for TBHQ, BHA, and BHT), and reproducibility (3.87, 0.90, and 2.92% for TBHQ, BHA, and BHT). To enable the application of this methodology in mayonnaise, it was optimized the clean-up of the sample conditions, which were 200 mg of mayonnaise mass, 280 µL of solvent extract, agitation at 5 speed for 20 min, and centrifugation at 6000 rpm for 20 min, resulting in the recoveries of 79.23±0.72, 96.98±2.21, and 92.75±5.24% for TBHQ, BHA, and BHT, respectively. The proposed methodology enabled the extraction of these compounds from margarine, oil, ketchup, and mayonnaise samples, with recoveries ranging from 70 to 120%. Therefore, extraction using the DPX with subsequent determination using HPLC-UV for synthetic antioxidants demonstrates several advantages, including reduced sorbent, solvent, and sample quantities, rapid extraction, low cost, and no need for a vacuum system, in line with Green Analytical Chemistry principles.
Views per month
Galoá count, excluding known robots. Updated on 22/11/2026.
Views per month
Galoá count, excluding known robots. Updated on 22/11/2026.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper