Abstract

Whole coconut water is a natural drink appreciated for its flavor and for having substances beneficial to health in its composition. Among them, phenolic compounds, a broad class of secondary metabolites of plant origin. Ingestion of these compounds has been linked to reduced effects of aging, cancer prevention, and cardiovascular disease. The determination of total phenolic (TF) content in beverages is commonly performed by the Folin-Ciocalteu method. However, there are no reports in the literature about the validation of this method for the analysis of coconut water,  an essential step to ensure the reliability of the results regarding the precision, accuracy and influence of possible interferents. The evaluation of interferents is particularly relevant considering the presence of reducing sugars in concentrations close to 5% in the beverage, and that the interference of these sugars has already been reported in matrices such as wine. In view of the above, the present study aimed to evaluate the accuracy and precision of TF quantification in coconut water, using the Folin-Ciocalteu method. The precision was estimated based on the comparison of the Coefficient of variation of the determinations, C.V.(%), with the limits proposed by the Horwitz equation, C.V.(%)H. The accuracy and possible effect of interfering agents were evaluated by means of the recovery test, with the addition of gallic acid P.A. to coconut water at concentrations of 1,00.10-5, 2,00.10-5 and 4,00.10-5 grams of gallic acid equivalents per mL (gEAG/mL). For the study, five immature fruits from the Green Dwarf coconut palm of Ponta do Seixas were used, supplied by a producer from the city of Conde (BA). Analyses were performed in triplicate. Spectral readings were taken using a Thermo Scientific Genesys 10S UV-VIS spectrophotometer. The total phenolic content obtained was 3.89×10−5 gGAE/mL, with a C.V.(%) of 2.57%. For concentrations of this magnitude, the expected C.V.(%)H is between 2.07 and 2.76%, indicating that the method's precision is within recommended limits. Regarding recovery, the values obtained were 102.34% (addition of 1.00×10−5 gGAE/mL), 107.39% (addition of 2.00×10−5 gGAE/mL), and 102.42% (addition of 4.00×10−5 gGAE/mL), all within the specified range (80 to 110%) for this magnitude of values. These results demonstrate that the Folin-Ciocalteu method exhibits good precision and good recovery (indicative of accuracy) for the analysis of phenolics in coconut water, and that potential interferences from other constituents do not compromise its reliability.

Share your ideas or questions with the authors!

Did you know that the greatest stimulus in scientific and cultural development is curiosity? Leave your questions or suggestions to the author!

Sign in to interact

Have a question or suggestion? Share your feedback with the authors!

Institutions
  • 1 Embrapa Tabuleiros Costeiros
Track
  • Chemical and Physico-chemical Food Characterization (FQ)
Keywords
Total phenolics
Coconut water
Analytical validation