Para citar este trabalho use um dos padrões abaixo:
Enantioselective analysis of the pesticide imazamox in permeability study with CACO-2 cells: chiral separation optimization and method validation
Carolina Oliveira Serpellone
Departamento de Química / Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto / Universidade de São Paulo
Agora você poderia compartilhar comigo suas dúvidas, observações e parabenizações
Crie um tópicoPesticides application in agricultural production is a widely resource used around the world to protect crops and reduce considerable losses caused by pests. Nevertheless, their intense use puts the environment and non-target organisms at risk. Imazamox (IMX) is a chiral herbicide used against weeds in cereal and oilseed crops in their pre- or post-emergence. The commercialization of this pesticide is allowed in several countries of the European Union, in the United States and Brazil. However, data on the exposure and enantioselective interaction of IMX with non-target organisms are scarce. In addition, there are no studies regarding the enantioselective behavior of IMX in human models. This work presents the development, through experimental design, of an enantioselective method to analyze IMX in acceptor solution to further study its permeability through CACO-2 cells. Initially, three chiral columns (Chiralpak-AD-H, Chiralcel-OD-H and Chiralcel OJ) were evaluated in polar organic and reverse modes, using 3 solvents: methanol, ethanol and acetonitrile. In the screening stage, fractional factorial planning was used by evaluating the following factors at two levels: (i) solvent proportion in mobile phase, (ii) percentage of formic acid, (iii) flow rate, (iii) temperature and (iv) volume of injection. In the optimization step, the central composite rotational design (DCCR) was used. Following the development of the enantioselective separation, the analytical validation was performed in order to analyze the IMX in permeability studies with CACO-2 cells. The following parameters were evaluated: linearity, lower limit of quantification, precision, accuracy, stability, selectivity, and residual effect. The acceptability criteria for each parameter were based on the ones described in the ANVISA validation guideline for bioanalytical methods. The final and optimized chromatographic condition was reached by using the Chiralcel OD-H column and H2O:ACN, 79:21 (v/v) was used as mobile phase. The flow rate was 0.6 mL min-1 and the column temperature was set at 30ºC. The resolution obtained was greater than 1.5 for the IMX enantiomers and the analysis time was less than 12 minutes. Based on ANVISA’s bioanalytical validation guide all the parameters were satisfactory and the method was considered validated.
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo