Introduction: The use of oscillometric method using digital devices for measuring blood pressure has a wide applicability in different scenarios. However, these measurements may be influenced by some factors, such as the patient's movements, physiological variations, and the equipment. Thus, it becomes necessary to compare the measurements provided by digital devices with the auscultatory method using mercury sphygmomanometer. Objectives: To compare the measurements of systolic and diastolic blood pressure obtained by digital device with mercury sphygmomanometer. Methods: Participated in the study 22 older men (age: 67.4 ± 4.8 years; body mass: 79.4 ± 13.1 kg; stature: 166.9 ± 8.3 cm), members of a program of regular exercise. Three measures of systolic and diastolic blood pressure (1, 2, and 3) were obtained by digital device More Fitness and mercury sphygmomanometer in counterbalanced design. The interval between the measurements was of two minutes. Two “blind” evaluators recorded values of systolic and diastolic blood pressure. Results: The auscultatory and oscillometric methods showed significant differences between the measures 1, 2, and 3 (p < 0.05) for systolic (140.6 ± 18.3 vs. 146.9 ± 19.1 mmHg; 139.5 ± 18.4 vs. 146.5 ± 14.3 mmHg; 137.4 ± 18.6 vs. 144.4 ± 18.2 mmHg; respectively) and diastolic (p < 0.05; 79.1 ± 10.3 vs. 87.9 ± 7.6 mmHg; 79.5 ± 10.1 vs. 87.1 ± 7.8 mmHg; 80.1 ± 10.4 vs. 88.3 ± 10.7 mmHg; respectively) blood pressure. Positive and significant correlations between the methods were observed for systolic and diastolic blood pressure (r = 0.66 and r = 0.64; p < 0.05). The mean differences (± standard deviation) for systolic and diastolic blood pressure between auscultatory and oscillometric methods were -6.8 ± 14.5 mmHg e -8.2 ± 8.1 mmHg, respectively. Conclusions: The results of this study indicate that systolic and diastolic blood pressure present different values when obtained by oscillometric and auscultatory methods, suggesting caution when using digital devices to measure blood pressure in older people.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper