77528

Sustainable and heuristic approach for Cynara scolymus L. (Asteraceae) metabolic fingerprinting by RP-HPLC-PAD: a tradeoff between separation and greenness

Favorite this paper

Globe artichoke (Cynara scolymus L.) is an herbaceous plant whose leaf extracts have been used in folk medicine for centuries, mainly due to its choleretic, antioxidant and hypocholesterolemic activities. At analytical investigations involving this medicinal plant, acetonitrile (MeCN) is the main used solvent, which is polluter, expensive and toxic. Thus, it would be convenient replace this harmful solvent by biodegradable and renewable alternatives such as ethanol (EtOH), widespread in Brazil. Besides, a time and resource-saving, heuristic and multivariate approach employing Design of Experiments must drive the development of fingerprint of this complex matrix aiming to a pattern for quality control and development of herbal medicines, covering Green Analytical Chemistry (GAC) principles. So, in this context, 50 mg of the extract of the artichoke leaves [prepared by maceration with 3 aliquots of 100 mL of EtOH/H2O 7:3 (v/v) during 144h] were solubilized in 1 mL of EtOH/H2O 7:3 (v/v) and applied to Sep-Pak C18 cartridge (Phenomenex®), previously activated with 6 mL of EtOH and equilibrated with 6 mL of EtOH/H2O (7:3, v/v). The sample in the cartridge was eluted with 2 mL of the equilibration solution and filtered in PTFE microfilter (0.45 μm). XBridge column (Waters®) with guard-column was used as stationary phase and EtOH and Millipore H2O with acetic acid were used as mobile phases. Aliquots of 20 μL were injected into the HPLC-PAD system. A Four-Factor Doehlert Design (more economic) was employed and the evaluated independent factors regarding HPLC gradient were X1(% initial of EtOH), X2 (Temperature, °C), X3 (% acetic acid on H2O) and X4 (flow-rate, mL min-1). Number of Peaks (NP) and Green Chromatographic Fingerprinting Response (GCFR, related to distribution of peaks along the chromatogram) were chosen as responses to be maximized. Multivariate estimated models regarding NP and GCFR responses presented significant regression (with explained R2 of 0.84 and 0.91, respectively) and did not presented lack of fit at 95% of confidence. The Response Surface Methodology indicated that the optimal chromatographic conditions for metabolite separation were 5% for X1 and 35°C for X2, whose experimental confirmatory runs were close to the predict values (the highest relative error was 8%). Chromatographic analyses had % final of EtOH, X3 and X4 fixed in 50,0.5 and 1, respectively, because these values allowed better resolutions and peak shapes for the fingerprint, developed at ʎ=350 nm. The reporter method allowed the identification of the active compounds through UV spectra (e.g. 1,3-di-O-caffeoylquinic acid). This method had an environmental impact until 76% lower than literature HPLC methods (according to HPLC-EAT metrics scores) proved to be compatible even with non-state of art instruments and using EtOH as organic solvent and presented good instrumental precision and repeatability (with maximum relative standard deviations of 0.65% and 1.01%, respectively).Therefore, we were able to cover 7 of the total 12 principles of GAC: 5th using and automated HPLC system to speed-up the development of fingerprint, as well carry out a miniaturized sample treatment and get analytical precision; 6th without derivatization of non-volatile compounds; 7th prevening the generation of a large amount of analytical waste through the employed Doehlert Design;8th and 9th saving resources and time by multivariate analysis; 11th with replacement of MeCN by non-toxic EtOH and, finally, 12th with increasing of the safety of the analyst.

ACKNOWLEDGEMENTS

São Paulo Research Foundation (FAPESP) for grants 2015/20639-1 and 2016/08179-8

REFERENCES
[1] Gebhart, R. Med. Sci. Mon. 7:316–20,2001; [2] Negro, D. et al. J. Food Sci. 77:244-252, 2012; [3] Funari, C.S. et al., J. Sep. Sci. 2014, 37, 37–4; [4] Barros Neto, B.et al., Bookman,2010