During the operation of a fusion reactor, energetic neutral particles are produced via charge exchange processes or through recombination. These fast-moving neutrals are not confined by the magnetic fields of the reactor. Their interactions with the plasma-facing components (PFCs) cause the erosion of the vessel walls and the release of impurities in the plasma [1, 2]. In addition, they contribute to fuel retention in the vessel walls [3]. The present work describes a methodology to measure the energy distributions of charge-exchange fluxes, with intended future applications in the ASDEX-Upgrade [4] and W7-X [5] fusion devices.
The quantification of total CX fluxes can be achieved by exposing collector probes in the reactor and the subsequent analysis of these samples via Ion Beam Analysis techniques. However, the determination of the corresponding energy distributions is challenging. The energies of the CX fluxes range from a few eV to a few keV. Therefore, these studies require the determination of depth profiles of implanted hydrogen isotopes with a depth resolution in the order of a few nm.
In the present work, amorphous carbon samples were implanted with monoenergetic deuterons for energies between 200 and 1000 eV in 200 eV increments. The implantations were carried out at the Max Planck Institute in Garching, Germany using the SIESTA high current source and target chamber [6]. Subsequently, these samples were analyzed with Time of Flight Elastic Recoil Detection Analysis (ToF - ERDA) in the Accelerator laboratory of the University of Jyväskylä [7]. A 1.7 MeV Pelletron accelerator was used to produce a 6.8 MeV 63Cu beam. The experimental setup consists of a target chamber, two timing detectors and an energy detector. The timing detectors consist of thin carbon foils with ALD coating to enhance the secondary electron emission with a combined resolution of less than 200 ps. The energy detector is a gas ionization chamber with a 100 nm thick Si3N4 window. Two beam incidence angles were used, 5ο and 10ο. A depth resolution of ~2 nm at the surface was achieved, enabling the clear separation of deuterium depth profiles for implantation energies differing by only 200 eV (Fig. 1). Simulations with the SDTrimSP [8], SRIM [9] and MCERD [10] codes were also performed.
In order to develop a deconvolution procedure to determine the incident energy distribution from the implantation depth profile, two additional samples were prepared. The first sample was irradiated consecutively with a 200, 600 and 1000 eV deuteron beam. The second sample was irradiated with a 5.2 keV deuteron beam while a triangle sweep bias (voltage setpoint at 3.4 kV, amplitude of 1.2 kV) was applied to the target. This resulted in a flat distribution of deuteron energies from 200 to 1000 eV. The energy distributions of the deuterons implanted in these two samples were reconstructed using the measured single-energy deuteron depth profiles as a basis for a non-negative least square fit. The reconstructed distributions successfully reproduce the known implantation conditions, demonstrating the capability of our methodology to determine the energy distributions of CX neutrals in fusion reactors.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper