To cite this paper use one of the standards below:
The Isotopic Geology Laboratory at the Federal University of Rio Grande do Sul (LGI-UFRGS) has been analyzing stable isotope of O and H in waters and C and O in carbonate samples over the past decade. This work describes how these analyses are performed at LGI. The isotopic composition (R) of a given sample is defined as the ratio between the amount of the rare isotope and the amount of the most abundant isotope. For C, O, and H, R is expressed as 13C/12C, 18O/16O, and 2H/1H, respectively. The deviation of the isotope ratio of a sample from the R ratio of a standard is represented by the δ (delta) notation, given by: δ=((Rsample- Rstandard)/Rstandard))x1000, where R is the isotope ratio between the rare isotope and the most abundant isotope of the sample and/or standard. For C, O, and H, delta is represented by δ13C, δ18O, and δ2H, respectively. Numerical values of δ are reported in permil (‰). At LGI, the analyses are performed using an Isotope Ratio Mass Spectrometry - Delta V Advantage - GasBench II, from Thermo Scientific®. For the determination of δ18O and δ2H in water samples, the method considers the equilibrium method between CO2– H2O and H2-H2O, respectively (Martins et al., 2023). For O analyses in waters, 500 µL of sample are added to a 10mL tube, and the samples and standards are placed in the autosampler tray at a temperature of 25°C±0.1°C. The next step is to flush the system to replace the atmospheric air inside the tubes with a special gas mixture of CO2/He (0.5% CO2 in He 4.6) at a flow rate between 100 and 150 mL/min for 5 minutes per tube. Subsequently, it is necessary to wait 18 hours to reach equilibrium, given by the following reaction: 2H218O(l)+C16O2(g)↔H216O(l)+C16O18O(g). He gas is used as a carrier gas, and CO2 serves as the reference gas. After validating the equipment control parameters, the automatic sequence of analyses is performed. To determine δ2H in water, 200µL of sample is added to a 10mL tube. Afterwards, a platinum catalyst is added to prevent the formation of H2S and remove water molecules adsorbed on dissolved organic carbon. The samples and standards are then placed in the autosampler tray at a temperature of 25°C±0.1°C. The system is flushed with a special gas mixture H2/He (2% H2 in He 4.6) at a flow rate between 100 and 110 mL/min for 5 minutes per tube. Subsequently, it is necessary to wait 40 minutes to reach equilibrium, occurring according to the following reaction: 1H2(g)+ 1H2HO(l)↔1H 2H(g)+1H2O(l). He gas is used as a carrier gas, and H2 gas serves as the reference gas. Additional correction is required for H analysis due to isobaric interference generated from the formation of mass 3 ions produced in the source. After validating the equipment control parameters, the automatic sequence of analyses is performed. The results of C and O in carbonates are obtained in a single analysis. Around 300 µg of pulverized sample is added to a 12 mL tube. The sample and standard tubes are placed in the sampler at a temperature of 70°C. After flushing with He gas (99.999%) for 5 minutes at a flow rate of 110 ml/min, approximately three drops of concentrated and moisture[1]free phosphoric acid are added to each tube to react with the carbonate sample, according to the following equation: 3CaCO3(s)+2H3PO4(l)↔Ca3(PO4)2(l)+ 3CO2(g)+3H2O(l). The reaction time for each sample is one hour. From this, the CO2 gas produced in the tube is analyzed. The results are stored in the registry system, evaluated through statistical treatments, and normalized through calibration curves using the VSMOW scale for water analyses and the VPDB scale for carbonate analyses. The main standards used are: NBS18 (δ13C=- 5.01‰VPDB; δ18O=-23.20‰VPDB), IAEACO1 (δ13C=2.49‰VPDB; δ18O=-2.40 ‰VPDB) for carbonates, and VSMOW (δ18O=0‰; δ2H=0 ‰) for waters. Water and carbonate control samples are analyzed for each batch of samples. The results show satisfactory reproducibility
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper