To cite this paper use one of the standards below:
The conventional bioreactor using Impeller type Rushton is the most employed of all bioreactors at all production ranges, especially in aerobic cultures where aeration and agitation are essential to supply the demand for oxygen by microorganisms. In order to ensure adequate hydrodynamic conditions, which maximize the oxygen transfer, minimizing the consumption energy and mixing time, this work evaluated the performance of two types of impellers – commercial Rushton (RT) and a 3D printed Rushton with modified blades (MRT) - with respect to kLa, power consumed and mixing time in differents aeration and rotation. The values of kLa under the same conditions did not change significantly, however when using the MRT impeller a constancy in power consumption was observed when comparing the aerated with the non-aerated system. The results indicate that the MRT blade geometry is the most efficient to mixing time in non-aerated systems, coming to be 26.5% lower at 100 rpm. Therefore, in the range of rotation and aeration studied, MRT is economically advantageous, since it provides similar results with low manufacturing cost.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper