INVESTIGATION OF EMULSION BREAKING METHOD FOR THE DETERMINATION OF TRACE METALS IN GASOLINE BY HIGH-RESOLUTION CONTINUUM SOURCE FLAME ATOMIC ABSORPTION SPECTROMETRY
Among other parameters for assessing the quality of gasoline, contamination with metals such as Pb, Cu and Fe is very important. In the case of Pb in gasoline its presence can poison the catalysts based on metals such as Pt and Pd, in engines of automobiles, while Fe and Cu can cause catalyzed oxidation reaction of gasoline favoring the formation of gum.1 The ANP Resolution No 5/2001 stipulates that the maximum permitted level of lead in gasoline samples is 5 mg kg-1.2 For Fe and Cu, contents have not yet been specified. The use of high-resolution continuous source flame atomic absorption spectrometry (HR-CS F AAS) technique indicates the possibility of improving these determinations, as a rapid sequential multielement routine determination can be implemented. In this work the determination of Pb, Cu and Fe in gasoline samples by HR-CS F AAS using extraction / pre-concentration based on emulsion breaking was investigated. The extraction of metals was carried out with emulsification of gasoline samples using Triton X-100 and HNO3 followed by emulsion breaking by heating. After emulsion breaking the aqueous phase was collected and used for quantification of metals by HR-CS F AAS. Different parameters that influence on the extraction efficiency were optimized using Doehlert design. The evaluated variables were: concentration of surfactant, concentration of HNO3 and the temperature employed in the process. The optimized conditions for preparing the emulsion breaking were: 10 mL of gasoline with 2.0 mL of solution containing 12 g mL-1 Triton X-100 acidified with 5% HNO3. The optimized temperature for emulsion breaking was 90°C for 10 minutes and approximately 3.5 ml of the aqueous phase was collected and used for analysis. In order to evaluate the extraction efficiency a gasoline sample was spiked with a known concentration of each analyte and submitted to three successive extractions. The result of the first extraction showed an extraction efficiency ranging from 80 to 89%. The precision was also satisfactory (rsd < 7%). The calibration curves were constructed aqueous standards added in the emulsion obtained with a gasoline samples free of analytes. Limit of Detection obtained was 4.9, 1.1 and 1.8 g kg-1 for Pb Cu and Fe respectively. The proposed method was simple, fast and suitable for routine analysis.