55053

Characterization of the steel used in hypodermic needles and possible contaminants by inductively coupled plasma optical emission spectrometry

Favorite this paper

Hypodermic needles are used in high amounts for a variety of procedures in the health system which makes them a strategic product for the Unified Health System - SUS. They are classified according to the Brazilian National Agency of Sanitary Vigilance – Anvisa as products that offer medium risks to the patient and/or user, and must, according to national norms ISO 7864/2010 and NBR ISO 9626/2003, have their cannulae made of austenitic stainless steel, in order to comply with the limits established in Resolution – RDC No. 5 of 2011 regarding the composition and presence of contaminants. The most common austenitic steel permitted for needle cannulae manufacture is steel 304. Since hypodermic needles are invasive products, evaluation of their composition is extremely important, since they will come into direct contact with the bloodstream in many procedures. The present study aimed to evaluate the quality of the steels and identify the presence of possible contaminants in the composition of national hypodermic needles. Samples from different brands were digested with royal water and an inductively coupled plasma optical emission spectrometer - ICP OES, Perkin Elmer model 8300, was used to determine all elements of interest. The analytical performance of the proposed method was verified by comparing the results with those obtained by X-ray fluorescence, which is the recommended technique for characterization of metallic alloys. The analytical results demonstrated that 49.2% of the 30 analyzed samples presented some deviation from 304 steel compositions, and 86.2% presented alterations in the major components Iron and/or Chromium. All the investigated brands showed unexpected metals in their composition and Mn percentages lower than that established in the current norm. It was also possible to observe an absence of uniformity with respect to minor constituents, both between brands and intra-brands. Although changes were observed in the major constituents Iron and/or Chromium and in Mn concentrations and some metallic impurities were present in the composition of the needle cannulae, the study proved that all cannulae were produced with 304 steel and are in accordance to the current legislation. The results obtained by ICP OES were compared to those obtained by RX fluorescence, and confirmed that ICP OES is an adequate technique for quality control of hypodermic needles.