Cortisol is a steroid hormone, secreted by adrenal gland that plays an important role in physiological processes regulation such as inflammation, blood pressure and glucose levels. Therefore, in severe stress, there is a considerable high production of this hormone in human, which is why popularly it is called “stress-hormone”, indicating that cortisol could be a good biomarker to measure the stress level in biological fluids1. Hence, cortisol monitoring is important and new strategies have been developed to cortisol quantification, such as electrochemical techniques, due their facility and simplicity2. Additionally, paper-based devices have attracted great attention in analytical chemistry due their interesting advantages, such as low-cost, easy fabrication, operational simplicity, besides being disposable devices, where it is possible to use as portable platform for electrochemical measurements3. In this work, initially, a glassy carbon electrode was used to investigate electrochemical behavior of cortisol in a conventional electrochemical cell using 0.1M acetate buffer solution pH = 4.5 as electrolyte. In this case, cortisol exhibited an irreversible reduction process around -1.30 V versus Ag/AgCl(KCl 3M) using Square Wave Voltammetry (SWV) technique. However, reproducible measures were not attained due the strong adsorption effect, hindering the electrode surface renovation. Therefore, a disposable sensor was developed to circumvent this drawback in the cortisol sensing. We fabricate a low-cost paper-based device using a chromatography paper and wax printing technology. The pseudo-reference electrode was painted using conductive silver ink. After that, the printed paper was heated in a stove for 30 min at 80 ºC. Then graphite leads were used as working and counter electrodes. Electrochemical tests using SWV method were performed in 0.1M acetate buffer solution pH = 4.5 as electrolyte. It was observed that the cortisol reduction peak appears at approximately -1.50 V vs Ag. In addition, potassium ferricyanide was used as internal standard to correct lack of reproducibility associated with the fabrication process providing low standard deviations when the devices are single used. A linear range of 10 - 100 μmol L-1 was achieved, showing a great potential of these devices for cortisol analysis.
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo