Measuring lipid volumetric expansion (LVE) in pressurized CO2 is useful for understanding processes such as lipid particle formation via supercritical CO2 technologies. However, performing this measurement can be a delicate and time-consuming task, so alternative strategies are needed. This research was conducted to explore LVE measurement strategies in supercritical CO2 as a function of pressure and contact time. The LVE (%) was the percentage change in volume with respect to the initial volume at 1 bar when the sample was in a thin tube inside an autoclave (at 60 °C) with sapphire window under supercritical CO2 at fixed pressure-contact time conditions. Brazil nut oil was used as a lipid model because of its application for particle formation in supercritical CO2. Three LVE measurement strategies were evaluated: 1) monitoring at constant pressure, as a control, at 150, 200, 250 and 300 bar for 300 min, 2) response surface by Central Composite Rotatable Design (2^2+2*2+2), to use few pressure-contact time conditions, in a range of 120-330 bar and 0-300 min and 3) scanning at upward pressures, to work pressure by pressure in a single run, from 75 to 300 bar for 540 min. Through monitoring, the LVE kinetic was explained by Peleg's model (R^2>99%, K_1(min/%): 0.65-0.30 and K_2(1/%): 0.025-0.017), while other strategies did not allow the evaluation of kinetic. The LVE values at equilibrium were 36.1±0.9, 41.7±0.9, 46.7±0.8 and 53.5±1.1 by monitoring, 37.8, 44.0, 50.2 and 56.4 by response surface (quadratic model, R^2=0.874, p=0.00) and 33.9±0.7, 40.3±0.4, 46.0±1.3 and 53.2±1.0 by scanning, in pressures of 150, 200, 250 and 300 bar, respectively. Response surface and scanning returned LVE values close to monitoring. Scanning is recommended as a rapid and practical strategy for experimental measurement of LVE, which could produce voluminous data for complex phase studies.
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo