Use of statistical design of experiments to evaluate the removal of cholesterol from milk for adsorption in column
The objective of this study involved the use of factorial design technique to investigate operating conditions which would conciliate a high removal of cholesterol from milk in adsorption column. An adsorbent prepared from molecular imprinting polymer (MIP), 0.250 mm granulometry, was used to column (continuous flow) on removing cholesterol. The influences of operating parameters like bed high (or adsorbent dosage) and volumetric flow were analyzed. The set of designed experiments was create using STATISTIC software (v. 8.0). The experimental factors and their respective levels that were selected include a bed high of 1-3 cm, a flow rate of 3–9 mLmin-1. The cholesterol removal was calculated for various contact times, such as 0.08 h, 0.16 h, 0.025, 0.5 h, 1 h, 2 h, 3 h, 4 h, 6 h. Were developed several models to differents contact time of adsorption process and the results were analyzed statistically using the analysis of variance and F-test. The results show that the responses of cholesterol removal (%) in adsorption column was significantly affected by bed column (adsorbent dosage) and flow rate in the early times of the adsorption process.