57112

Mn(III)-Porifina como Mediador Redox na Eletrocatálise de Redução do H2O2

Favoritar este trabalho

Enzyme model-based amperometric sensors have attracted the interest of many researchers by its low-cost, simplicity, and high sensibility and selectivity. Metal complexes could be used for this purpose, and porphyrin-based biomimetic models have shown to be versatile redox mediators on such electrodes.1 Hydrogen peroxide (H2O2) is a product of some important enzymatic reactions, being of relevance in medicine, environmental science, and food technology. 2 Thus, H2O2 is a common target in biosensors research. In this work, carbon paste electrode (CPE) was modified with meso-tetrakis(N-methylpyridinium-4-yl)porphyrinatomanganese(III) chloride (MnTM-4-PyPCl5, MnP) to yield CPE-MnP, which was characterized electrochemically and used for the electrocatalytic reduction of hydrogen peroxide. CPE-MnP was prepared by adding 100 μL of a 1.30 mmol L-1 aqueous solution of MnP onto a mixture of 60 mg of graphite powder and 40 mg of mineral oil. Cyclic voltammetry (CV) was carried out in 0.5 mol L-1 NaCl(aq) from –1.2 V to 0.0 V, with a scan rate of 100 mV s-1 , a platinum auxiliary electrode, and a saturated calomel electrode (SCE) as reference. CV showed a quasi-reversible redox behavior for the metal centered MnIIIP/MnIIP process, with a formal potential [(Ep red + Ep oxi)/2] of -0.639 V. A linear behavior of reduction peak currents versus the square root of scan rates indicates that the electrochemical processes are diffusion controlled. The influence of the concentration of NaCl (from 0.1 mol L-1 to 0.5 mol L-1 ) on the electrochemical behavior was studied, and the best NaCl concentration was 0.5 mol L -1 . The electrocatalytic reduction of H2O2 was evaluated by CV and chronoamperometry. CV shows that H2O2 reduction occurs at –1.24 V with CPE-MnP electrode, as opposed to –1.40 V with unmodified CPE. An optimization of the applied potential for chronoamperometric measurements was performed by evaluating the following potentials: –1.25 V, –1.20 V, –1.15 V and –1.10 V. The best catalytic response was observed at –1.20 V. The analytical curve showed two linear regions: i) from 20 mol L -1 to 120 mol L-1 ; ii) from 0.20 mmol L-1 to 2.10 mmol L-1 ; for the higher concentration region, the sensitivity was 6.9 μA L mmol-1 . The LOD and LOQ values were estimated as 5.8 μmol L-1 (3(S/N)) and 19.2 μmol L-1 (10(S/N)), respectively. In this work MnTM-4-PyPCl5 was established as a simple, commerciallyavailable, and stable modifier to CPE to yield a low-cost sensor with good sensitivity, LOD, and LOQ for H2O2 detection in aqueous system.