56917

Electrochemical Disinfection of Synthetic and Urban Wastewater. Use of Single and Combined Processes.

Favoritar este trabalho

The electrochemical disinfection has gained much progress in recent years as a water disinfection technology characterized by easy and mild operation conditions, along with environmental compatibility and the in-situ production of oxidants. The most relevant parameter in the electro-oxidation (EO) of water contaminated with bacteria is the anode material, being boron-doped-diamond (BDD) the most promising one. The use of other electrochemical technologies such as electrocoagulation (EC) and electro-Fenton (EF), alone or combined, opens different interesting alternatives. This communication presents relevant results found in our laboratory by applying the above methods to inactivate common bacteria [1,2]. EO with a BDD anode was used to treat 100 mL of 7 mM Na2SO4with 106 CFU mL-1of bacteria at 33.3 mA cm-2. A quick disinfection process was obtained for Gram-negative (Escherichia coli and Pseudomonas aeruginosa) and Gram-positive (Bacillus atrophaeus) bacilli, whereas Gram-positive cocci (Staphylococcus aureus and Enterococcus hirae) were more resistant to the attack of physisorbed•OH. SEM highlighted the inactivation of cells with a highly altered morphology lying on dirty filters with plenty of cellular debris. Larger damage was observed for Gram-negative cells, indicating that inactivation can be related to the chemical composition of the outer layers of the cell structure and the modification of the transmembrane potentials upon current passage. A study on Pseudomonas aeruginosa suspensions in 7 mM Na2SO4at pH 5.8 by EO revealed a faster inactivation with DSA® as compared to BDD by the larger adsorption of bacteria at the surface of the former anode, favoring the oxidation with physisorbed•OH. Similar results were found by adding paracetamol. Best performance was obtained in 7mM Na2SO4+ 7 mM NaCl at 8.3 mA cm-2, with total inactivation in 2 min and energy consumption of 0.059 kW h m-3, due to the contribution of active chlorine. EC and/or EF were used to disinfect urban wastewater at pH 7.4. Best results were obtained by combining both methods. In primary effluents, Enterococci and Somatic Bacteriophages were rapidly inactivated and Clostridium perfringens was the most resistant. In secondary wastewater, such microbiota and Escherichia coli were totally reduced in 10 min, being the Heterotrophic Bacteria more persistent.