DIRECT DETERMINATION OF RARE EARTH ELEMENTS IN CRUDE OIL AND ITS FRACTIONS BY ETV-ICP-MS
The knowledge of concentration of rare earth elements (REE) in crude oil and its fractions is relevant for petroleum industry allowing to predict the origin as well as information about processing. In this context, a method using electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICP-MS) was developed for the determination of REE in crude oil. An ETV system (model ETV-4000c, Spectral Systems, Germany) with Freon R-12 was used to promote the vaporization of analytes and a homemade electronic valve was positioned between the ETV system and the ICP-MS equipment (model Elan DRC II, Perkin Elmer-SCIEX, USA).1 The furnace temperature program, bypass and carrier gas flow-rate, the sample mass introduced into the furnace and the feasibility to perform calibration using aqueous solution were evaluated. The pyrolysis and vaporization temperature were 700 °C and 2200 °C, respectively. Argon flow-rate of 0.35 L/min was chosen as bypass and as carrier gas, allowing higher signal intensities for all analytes. In order to expand the application of the proposed method, the influence of emulsified water and NaCl in crude oil was evaluated. For this, synthetic emulsions with water content of 5 to 30% were prepared. It was observed that emulsion containing up to 20% of water can be analyzed with precision and accuracy. In addition, the concentration of NaCl (10 µg/g to 2000 µg/g) dissolved in emulsion (5% of water) was evaluated. No statistical difference (student test, P < 0.05) was observed between the results obtained without and with NaCl (up to 2000 µg/g). The determination of REE by ETV-ICP-MS with reference solution was possible using citric acid (6 mg) as a carrier agent, allowing low relative standard deviation values (up to 10%). Results obtained by ETV-ICP-MS were compared with those obtained by microwave-assisted wet digestion with concentrated HNO3 and further analysis using ultrasonic nebulizer (USN) coupled to ICP-MS. The values obtained by ETV-ICP-MS presented good agreement with those values achieved by USN-ICP-MS. Limits of detection for REE ranged from 0.01 and 0.70 ng/g, which were essential for the determination of REE in low concentration in crude oil and its fractions. Therefore, ETV-ICP-MS method was feasible for the determination of REE in crude oil and fractions with different composition, such as diverse emulsified water and NaCl content, which is important for the petroleum industry.