Determination of Ca, K, Mg and Na in sports supplements employing chemometrics tools and direct solid analysis by Laser-Induced Breakdown Spectroscopy (LIBS)
Diego Victor De Babos
Universidade Federal de São Carlos
Agora você poderia compartilhar comigo suas dúvidas, observações e parabenizações
Crie um tópicoWatch this next:
Sports supplements as whey protein contain high protein content and are widely used by high-performance athletes and practitioners of physical activities for muscle regeneration. These supplements may also contain high concentrations of macronutrients such as Ca, K, Mg and Na, which play important physiological functions and therefore must be monitored to maintain a good functioning of the metabolism of users.1 LIBS, is an analytical technique that enables qualitative and quantitative fast analysis (<1 s), direct analysis or with minimal sample preparation and low generation of residues.2 Thus, new calibration strategies and chemometric tools were employed for the direct analysis of sports supplements using LIBS aiming at the determination of macronutrients Ca, K, Mg and Na. LIBS emission spectra of the analytes were obtained using an instrument model J200 (Applied Spectra, USA), with a Nd:YAG laser (1064 nm). Approximately 200 mg of each sample was used to obtain pellets using a press (70 kN for 2 min). A Doehlert factorial design with a central point was used to optimize the instrumental conditions for the analyte determinations, being evaluated delay time (0.8, 1.4 and 2 µs) and laser pulse fluence (368, 1422, 2476, 3530 and 4584 mJ cm-2) variables. The following emission lines were monitored: Ca (393.36 and 396.84 nm), K (766.49 and 769.89 nm), Mg (383.83 and 518.36 nm) and Na (588.99 and 589.59 nm), then overall desirability (using signal-background ratio for all wavelengths) was calculated and used as design response. The final instrumental conditions were delay time of 1.4 µs and fluence of 2476 mJ cm-2. Approximately 200 spectra (n = 3) were obtained for each sample, and twelve modes of spectral normalization were evaluated. All sports supplements were also analyzed by ICP OES to obtain reference values to assess the accuracy of direct determinations by LIBS. The concentrations determined by ICP OES were in the range of 3351 to 7069 mg kg-1 Ca, 3870 to 13639 mg kg-1 K, 626 to 2678 mg kg-1 Mg and 1293 to 5170 mg kg-1 Na. Three calibration strategies were evaluated for direct determination by LIBS: 1- matrix-matching calibration (MMC),3 2- one-point and multi-line calibration (OP MLC),4 and 3- single sample calibration (SSC).5 For the determination of Ca, MMC, OP MLC and SSC presented good values of trueness (68 to 119%) and RSD (2 to 30%). For K, OP MLC enabled the best trueness values (87 to 102%) and RSD (1 to 10%), except for some samples. For Mg, good trueness values (83 to 120%) and RSD (1 to 14%), with the exception of some samples, were obtained using MMC and OP MLC. For Na only using SSC presented reliable values for trueness (79 to 116%) and RSD (4 to 10%), for most samples. Unsatisfactory values of trueness were obtained for some elements in some samples due to the strong matrix effects in the LIBS determination. However, some calibration strategies evaluated were able to overcome or minimize the matrix effects for most determinations. The use of principal component analysis - PCA and LIBS spectra made it possible to observe two clusters of samples: high and low protein content in sports supplements. Fast, direct and green method is developed for the determination of macronutrients in sports supplements (whey protein) using LIBS.
[1] F.K. Haraguchi et al., Rev. Nutr., 19(4) (2006) 479-488.
[2] V.C. Costa et al., Quim. Nova, 42(5) (2019) 527-545.
[3] D. V. Babos et al., Spectrochim. Acta B, 155 (2019) 90-98.
[4] Z. Q. Hao et al., Opt. Express, 26 (2018) 22926.
[5] R. Yan et al., Anal. Chim. Acta, 1064 (2019) 11-16.
Hygor Marcos Ribeiro de Souza
Oi, Diego. Parabéns pelo trabalho e pela excelente apresentação. Eu fiquei apenas com uma dúvida: você calculou a exatidão a partir da recuperação?
Danielle S Francischini
Parabéns pelo trabalho Diego! Estudei na UFSCar e tive o prazer de conhecer o Prof. Edenir! Minha dúvida está na parte de validação do método de quantificação Single-point, vocês fazem através da comparação dos valores obtidos com àqueles via ICP-OES? Pergunto, pois trabalho com um método próximo via LA-ICP-MS e me pergunto sobre os limites de quantificação/detecção requeridos em uma validação (obtidos por curvas analíticas).
Abraços!!
Diego Victor De Babos
Muito obrigado Danielle!
Sim, para validação do método, nós utilizamos as concentrações determinadas nas amostras de suplementos esportivos por ICP OES (método de referência) para o cálculo da recuperação. A partir dos valores de recuperação, verificamos a exatidão das determinações obtidas por LIBS. Para verificar a precisão calculamos o desvio padrão relativo.
Sobre LOD e LOQ, para estratégias de calibração single-point, nós calculamos o erro puro que permite inferir a partir de qual concentração do analito é possível quantificar com exatidão satisfatória. Para a MEC, foi proposto recentemente o cálculo do LOD e LOQ a partir da propagação de erros (DOI: 10.1039/D0JA00212G).
Abraços!
Danielle S Francischini
Obrigada pela resposta! Irei ler este artigo e me basear, com certeza. Muito obrigada pela ajuda e desejo sucesso no trabalho de vocês!
Abraços!
Josué Carinhanha Caldas Santos
Prezado Diego e equipe,
Em nome da divisão de Química Analítica da SBQ, gostaríamos de parabeniza-los pelo trabalho apresentado, e agradecer pela disponibilidade e aceite do convite. Assim, esperamos nos encontrar no próximo ano na 44º RA da SBQ em Maceió – AL.
Abraços,
Josué, Márcia, Wendell e Paola
Diego Victor De Babos
Muito obrigado pela oportunidade!
Abraços
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo
Diego Victor De Babos
Olá Hygor. Muito obrigado!
Sim, nós utilizamos os valores das concentrações determinadas dos macronutrientes por ICP OES nos cálculos das recuperações, para verificar a exatidão das determinações por LIBS. Abraço.