34761

The use of portable NIRS instrument for in situ soil analysis and fertility diagnosis

Favorite this paper

Soil fertility diagnosis is usually conducted through the determination of soil physical, chemical and biological properties. The traditional methods of soil fertility diagnosis are quite tedious and time consuming. The portable NIRS could be used as an alternative method, as it provides timely in-situ estimation of various soil chemical and physical properties. Even if specific NIRS calibration exists for the determination of various soil parameters, there is little information on the use of in-situ portable NIRS for soil fertility diagnosis.
The aims of this study were a) to develop and calibrate equations (models) for the prediction of total carbon, total nitrogen, pH, the electrical conductivity (EC), the cation exchange capacity (CEC) and plant available phosphorus on selected wet and dry South-African soil samples; b) to validate the reliability of the models developed for NIRS using independent data sets.
A total of 320 soil samples were collected for the calibration and validation of models for NIRS from two contrasting sites in South Africa with contrasting climate, vegetation and soil types. The first site was located in the arid Kalahari area, which is characterized by low rainfall, and covered with vegetation dominated by grass and shrub species adaptable to the sandy soils. The second site is located in the sub humid area that has relatively higher rainfall and under a range of cropping systems (planted pastures and agronomic crops). The soils in the latter case are characterised by relatively higher clay content (clay loam to clay).
A portable NIR spectrometer ASD LabSpec 4 Standard-Res Lab Analyser (Analytical Spectral Devices, Boulder, CO, USA) with a high intensity contact probe was used to scan soil samples.
Soil spectral scans were carried out on fresh soils in-situ and on dry soils in the laboratory. Prediction models were then developed, independently, with dry and fresh base spectra and the results were compared.
Data analysis was conducted using the Unscrambler software 8.0.5 (CAMO Technologies, Inc., Woodbridge, NJ, USA), based on spectra with mathematical pretreatments (2nd derivative + SNV and smoothing).
Calibration models for each of the considered soil parameters of interest were developed from partial least square (PLS) regression and full cross-validation. The models were evaluated based on the values of R2 for predicted versus measured compositions, regression point displacement (RPD), and standard error in calibration and cross-validation (SEC- SECV).
Satisfactory predictions were achieved for total carbon (0.89≤R2<0.95, 1.8≤RPD≤3.7), total nitrogen (0.85≤R2<0.90, 1.7≤RPD≤2.9), CEC (R2≥0.90, RPD = 2.2–2.8) and EC (R2≥0.81, RPD = 2.0), but available phosphorus and pH were poorly predicted (RPD≤1.6). The best predictions were often obtained with the dry soil sample spectra.
However, promising results were obtained for the prediction of carbon, nitrogen and CEC using fresh soil sample spectra though the models need to be refined further for better prediction capabilities. It seems that soil moisture might have contributed to the poor model predictions of soil parameters on fresh soil samples.