To cite this paper use one of the standards below:
Extracellular vesicles (EVs) can contribute to the metastatic niche and modulate the immune response in several cancer types, including melanoma. The labeling of plasma-derived EVs from melanoma patients to melanoma (MART-1) and immune tolerance markers (HLA-G) can be used as a liquid biopsy strategy to determine the patient prognosis. Thus, we proposed to standardize the detection of MART-1 and HLA-G in plasma-derived EVs from patients with melanoma and nevi. The study was approved by the Research Ethics Committee (CAAE:64852022.1.0000.5243) and patients from the Dermatology Division of the Hospital Universitário Antônio Pedro/ESBERH with surgical resection indication were included. Blood samples were collected in 3,2% citrate tubes, processed by centrifugation, aliquoted and stored at -80ºC. For standardization of the nanoscale flow cytometry protocol, we used a pool of five plasma samples: three from melanoma and two from nevi. Samples were defrosted at room temperature and the pool was made with 40μL of each. EVs were isolated from 175μL of the pooled plasma by differential centrifugation (12.000xg 2 minutes 4ºC to obtain platelet-free plasma and 20.000xg 20 minutes 4ºC to obtain EVs). The supernatant was removed, and the pellet was resuspended with 150μL of Annexin Buffer (Invitrogen). Antibodies mix was prepared to EVs labeling with annexin V-FITC (Biolegend); anti-Human MART-1 Alexa Fluor 647 (BD Biosciences) or anti-HLA-G PE (eBioscience™) and annexin Buffer. To determine the best antibody concentration, we used 4μL of annexin V, and different volumes of anti-MART-1 and anti-HLA-G (2μL, 4μL e 8μL). After incubation and a final centrifugation, samples (1:10) were acquired using the CytoFLEX S (Beckman Coulter). Data analyses were done with FlowJo software. For the MART-1 antibody, the best result was seen with 4μL (110.000 events), with null results to others tested concentrations. For the HLA-G antibody, the events obtained were 17.500, 12.000 and 24.000, respectively, to the concentrations of 2μL, 4μL and 8μL. Therefore, the data suggest that the 8μL is a good start to HLA-G determination in plasma-derived EVs. However, for the MART-1 antibody, a new test is needed to improve the results.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper