Study of the Effect of Pre-Electrochemical Treatment on the Stability and Electrochemical Sensitivity of Laser-Induced Graphene Electrodes

Vol. 1, 2024 - 317629
Apresentação em Pôster
Favoritar este trabalho
Como citar esse trabalho?
Resumo

Laser-induced graphene (LIG) electrodes are promising alternatives for the fabrication of electrochemical sensors because of their good conductivity, high sensitivity, ease of production, and low cost. However, the porous structure of LIGs promotes the adsorption of species, which compromises their durability. This study aimed to evaluate the impact of electrochemical treatment on the long-term stability of these sensors. Electrochemical cells based on LIG were fabricated on Kapton polyimide tape, fixed to ceramic substrates, and the sensor was produced using a KKcare A5M50 laser engraving machine, resulting in a three-electrode system with a geometric area of 9.6 mm² for the working electrode. The active area was defined using insulating paint, and a pseudo-reference Ag/AgCl electrode was constructed using a commercial Ag/AgCl conductive ink (60:40) from Gwent Group. Intraday and interday repeatability studies were performed on 10 cells using Cyclic Voltammetry (CV) in the potential range of -0.2 to 0.5 V, with a scan rate of 0.1 V/s and five cycles in a 5 mM potassium ferrocyanide/ferricyanide solution, repeated daily for 20 days. Additionally, a CV with 120 scans was performed on the other cells. The diffusion coefficient for the ferro/ferricyanide probe was adopted as 0.77 x 10-5 cm²/s, based on previous literature values. The same electrochemical tests were repeated on cells subjected to an additional electrochemical surface treatment using 0.1 M phosphate buffer solution (PBS) at pH 7.2, applying a constant potential of -1.1 V for 60 seconds. The results showed that without treatment, the sensitivity to the ferro/ferricyanide probe decreased by approximately 53% in peak current over the days, whereas the PBS treatment limited the reduction to 5.5%. This study highlights the intrinsic vulnerability of LIG electrodes and proposes a simple solution for improving their stability.

Compartilhe suas ideias ou dúvidas com os autores!

Sabia que o maior estímulo no desenvolvimento científico e cultural é a curiosidade? Deixe seus questionamentos ou sugestões para o autor!

Faça login para interagir

Tem uma dúvida ou sugestão? Compartilhe seu feedback com os autores!

Instituições
  • 1 Universidade Federal dos Vales do Jequitinhonha e Mucuri
  • 2 Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM)
Eixo Temático
  • Sensores e Biossensores Eletroquímicos
Palavras-chave
Laser-induced graphene (LIG)
Electrochemical sensors
Stability improvement
Phosphate buffer treatment