Laser-induced graphene (LIG) electrodes are promising alternatives for the fabrication of electrochemical sensors because of their good conductivity, high sensitivity, ease of production, and low cost. However, the porous structure of LIGs promotes the adsorption of species, which compromises their durability. This study aimed to evaluate the impact of electrochemical treatment on the long-term stability of these sensors. Electrochemical cells based on LIG were fabricated on Kapton polyimide tape, fixed to ceramic substrates, and the sensor was produced using a KKcare A5M50 laser engraving machine, resulting in a three-electrode system with a geometric area of 9.6 mm² for the working electrode. The active area was defined using insulating paint, and a pseudo-reference Ag/AgCl electrode was constructed using a commercial Ag/AgCl conductive ink (60:40) from Gwent Group. Intraday and interday repeatability studies were performed on 10 cells using Cyclic Voltammetry (CV) in the potential range of -0.2 to 0.5 V, with a scan rate of 0.1 V/s and five cycles in a 5 mM potassium ferrocyanide/ferricyanide solution, repeated daily for 20 days. Additionally, a CV with 120 scans was performed on the other cells. The diffusion coefficient for the ferro/ferricyanide probe was adopted as 0.77 x 10-5 cm²/s, based on previous literature values. The same electrochemical tests were repeated on cells subjected to an additional electrochemical surface treatment using 0.1 M phosphate buffer solution (PBS) at pH 7.2, applying a constant potential of -1.1 V for 60 seconds. The results showed that without treatment, the sensitivity to the ferro/ferricyanide probe decreased by approximately 53% in peak current over the days, whereas the PBS treatment limited the reduction to 5.5%. This study highlights the intrinsic vulnerability of LIG electrodes and proposes a simple solution for improving their stability.
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo