PREVALENCE OF NEGATIVE GRAM BACTERIA IN STETHOSCOPES AND THE PRACTICE OF HYGIENIZATION BY HEALTH PROFESSIONALS IN A HOSPITAL OF PRESIDENTE PRUDENTE, SÃO PAULO-BRAZIL

Vol 2, 2018 - 95062
APRESENTAÇÃO DE PAINEL
Favoritar este trabalho
Como citar esse trabalho?
Resumo

Health services, particularly the hospital environment, present an environment with a potential risk of contamination by Gram-negative bacteria. . The transmission of these bacteria can be acquired through the air, droplets and mainly by contact in which the stethoscope is included and the handling of the hands. The objective is to identify the prevalence of Gram-negative microorganisms found in stethoscope diaphragms and to analyze the variables contained in the questionnaire that was applied. It comprises a descriptive cross - sectional study that evaluated 150 stethoscopes from a school hospital in western of the state of São Paulo. In addition, the study analyzed through a questionnaire the knowledge about the importance of the practice of hygiene of stethoscopes and hands by health professionals and students of the same hospital, applying a statistical method to compare them. It was found twenty-one stethoscopes contaminated with gram negative bacteria. Of the two hundred participants interviewed in the questionnaire, one hundred ten were health academics, including medical, nursing and physiotherapy academics, seventy nurses, fifteen physicians and five physiotherapists, and only fifty-two (47.27%) academics answered that disinfection of the appliance. Fifty-six (80%) nurses said they used to wash and disinfect. Eleven (73.33%) doctors also responded to disinfection. Four (80%) physiotherapists said they perform the cleaning and disinfection of the appliances. The difference in the habit of cleaning the stethoscopes between health professionals (physicians, nurses and physiotherapists) and academics from the same area was statistically significant, since the value found was <0.00001 (p <0.05), in which professionals has a greater habit of performing such a procedure. One hundred percent of all interviewees said that they wash their hands between each procedure, but 67.27% (seventy-four) of the academics, 51.42% (thirty-six) of the nurses, 93.33% (fourteen) of the physicians and 40% (two) of physiotherapists have ever forgotten to wash their hand. The study concludes that the prevalence is low (14%), and that the way and frequency of disinfection of the stethoscope are incorrect.

Eixo Temático
  • MICROBIOLOGIA MÉDICA
Palavras-chave
STETHOSCOPES
HAND DISINFECTION
GRAM-NEGATIVE BACTERIA