IMPROVING THE CHROMATOGRAPHIC SEPARABILITY OF ANTISCHISTOSOMAL PRAZIQUANTEL ENANTIOMERS BY SURFACE RESPONSE TECHNIQUE

Vol. 5, 2025 - 326873
Pôster
Favoritar este trabalho
Como citar esse trabalho?
Resumo

The present study aimed to evaluate the influence of relevant variables on the resolution of the enantiomers of the antischistosomal drug praziquantel (PZQ), employing response surface methodology and experimental design. It was observed that ethanol:hexane mixtures with increasing hexane content enhanced the enantiomeric separability, even under conditions of column overloading (high concentrations). Additionally, a retention increase of over 100% was observed for both enantiomers when compared to the reference condition reported in the literature. The results suggest that ethanol contents below 30% and concentrations above 25.0 g·L⁻¹ are feasible for preparative separations, which will be the subject of future investigations.

Compartilhe suas ideias ou dúvidas com os autores!

Sabia que o maior estímulo no desenvolvimento científico e cultural é a curiosidade? Deixe seus questionamentos ou sugestões para o autor!

Faça login para interagir

Tem uma dúvida ou sugestão? Compartilhe seu feedback com os autores!

Instituições
  • 1 Escola de Química, Universidade Federal do Rio de Janeiro (UFRJ)
  • 2 Universidade Federal do Rio de Janeiro
  • 3 Universidade Federal do Rio de Janeiro (UFRJ)
Eixo Temático
  • Termodinâmica e Separações
Palavras-chave
praziquantel
enantiomeric separation
experimental design
HPLC
preparative separation