INVESTIGATION OF THE FLUID AND PARTICLES FLOW INSIDE THE INLET DUCT OF AN INDUSTRIAL FABRIC FILTER USING CFD SIMULATION

Vol. 3, 2022 - 147553
Oral
Favoritar este trabalho
Como citar esse trabalho?
Resumo

CFD simulations were performed to analyze the influence of a by-pass attached to a duct system, which feeds a fabric filter, on the flow behavior of gas and hydrated lime injected into the duct, whose function is to assist in the fabric bags precoating. To evaluate such influence, a second scenario without the by-pass was also simulated. The result showed that the by-pass generates a disturbance in the flow, causing inhomogeneous distribution of the gas flow, formation of vortices and an increase in the pressure drop, which was confirmed by the second scenario simulated without the by-pass, where a reduction of 52% in the total pressure drop was obtained. Therefore, the study suggests that the by-pass can influence the precoating process and the performance of the fabric filter.

Instituições
  • 1 Sereng Engenharia e Consultoria
  • 2 ArcelorMittal Global R&D
  • 3 ArcelorMittal Global R&D Brazil
  • 4 Universidade Federal do Espírito Santo
Eixo Temático
  • Aplicações em CFD
Palavras-chave
Fabric Filter
Steelmaking
Emissions