To cite this paper use one of the standards below:
Honey is widely used worldwide for medicinal purposes or as a natural sweetener. It is a complex matrix consisting of around 200 substances, with approximately 85% of its content comprising sugars. Glucose and fructose are the major sugars, but honey samples can also contain maltose, sucrose, nigerose, turanose, kojibiose, and trehalose.1 The ratio between glucose and fructose is important for verifying the quality of honey and may indicate its ability to crystallize. Additionally, the amount of sucrose is an important indicator of quality2. As a powerful technique, NMR has been widely used for food analysis, either for qualitative or quantitative purposes. Quantitative NMR (qNMR) offers significant advantages compared to other techniques, especially due to its primary analytical characteristic.3 For this reason, most papers related to qNMR present a quantification process based on a direct relation between the analyte and an internal standard. Therefore, the aim of this work has been quantifying the amount of sugars using 1H NMR, compare the results between Brazilian and Canadian honey samples, and validate a methodology for the quantification process. Methodology validation requires good selectivity, linearity, precision, accuracy, detection and quantification limit, and suitable robustness for the analysis4. The qNMR spectra were acquired using three different equipment: a 9.4 T (400 MHz) Varian/Agilent spectrometer equipped with a 5 mm broadband probe, an 11.7 T (500 MHz) Bruker Avance III system featuring both with a 5 mm TXI probe and a 5 mm BBFO probe with auto-tune and match utilizing 90o pulse, and a 16.4 T (700 MHz) Bruker Avance III NMR spectrometer equipped with a 5 mm CPTCI cryogenically cooled probe. A comprehensive investigation was conducted on the relaxation delay to ensure that all signals utilized for sugar quantification achieved full relaxation during the quantification analysis. These preliminary results have affirmed that the sensitivity of the technique may be affected by the type of probe, analyte concentration, and magnetic field strength.The trimethylsilylpropionic acid (TMSP) was employed as the internal standard, and all analysis are being performed with 1 mL of 50 mM NaH2PO4/Na2HPO4 buffered D2O at pH 7.2, as the solvent. As part of the validation process, a calibration curve was constructed for each analyte using concentrations ranging from 1 mM to 8.5 mM at six different levels. Statistical analysis and other performance parameters are ongoing. The validation protocol will be applied to Brazilian and Canadian honey for comparison to assess any discernible differences.
References
Acknowledgments: CAPES, CNPq, FAPES, LabPetro and NRC Canada for financial support.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper