Validation of UHPLC-MS method for artepillin C quantification on green propolis
Artepillin C is the main chemical marker of Brazilian green propolis, which is produced especially in Minas Gerais by Apis mellifera using Baccharis dracunculifolia DC (Asteraceae) as the main botanical source. The high performance liquid chromatography coupled with photodiode array detector (HPLC-PDA) is often used for this purpose. The ultra high performance liquid chromatography coupled with mass spectrometry (UHPLC-MS) is a more advanced technique and has many advantages. However, there is not an analytical method in UHPLC-MS for quantification of artepillin C. The aim of this work was to validate an analytical method for quantification of artepillin C in green propolis by this technique. Chromatography was performed using H-Class Acquity UPLC® System (Waters), Acquity BEH C18 column and a temperature of 45 °C. The elution system was performed with a gradient using water and methanol (containing 0.01 % formic acid), flow rate of 0.4 mL/min and 14 minutes of analysis. The chromatography system was coupled with a Xevo G2-S Q-Tof mass spectrometer (Waters) equipped with an electrospray (ESI) ion source, which operated in the negative ionization mode. The optimized parameters were as follow: collision energy 25 eV; capillary voltage 3 kV; cone voltage 40 V; source temperature 150 °C; desolvation temperature 500 °C; cone gas flow 50 L/h; desolvation gas flow 1000 L/h. Quantification was performed using selected reaction monitoring (SRM) mode to monitor deprotonated molecular ion (m/z 299) -> fragment ion (m/z 200.12). The standard used for quantification was previously isolated by the our research group (purity 97.8 %). The method was validated according to the ANVISA RE 899 and ICH (International Conference on Harmonization) Q2 (R1) guidelines. Specificity of the method was assessed for any possible interference at the retention time of the artepillin C. Linearity was determined by analyzing calibration curve with the concentrations 50, 100, 200, 300 and 400 µg/mL by three replicates and range, detection and quantification limits were determined from the linearity. Intra-day precision and inter-day precision were expressed in terms of relative standard deviation (RSD %) of six samples replicates of green propolis samples. Accuracy was determined in terms of percentage recovery with spiking propolis samples with artepillin C at three concentrations levels. Robustness was evaluated by intentional modifications in the column temperature and flow rate of mobile phase. Results showed that methodology was specific, linear, precise, accurate and robust. Also, results obtained showed detection limit = 10.79 µg/mL, quantification limit = 32.70 µg/mL, RSD intra-day = 1,9 %, RSD inter-day = 3,4 % and recovery 93-104 %. The contained of artepillin C in green propolis was quantified in 6.51 % and this result is in agreement with data which uses HPLC-PDA. In conclusion, the validated method showed many advantages in comparison with HPLC-PDA, such as decrease in analysis time and selectivity of the MS detector for artepillin C. Acknowledgements: The authors are grateful to FAPEMIG and CNPq for financial support, as well as to CAPES, PIBIC/CNPq/UFJF and CNPq for fellowships.