Volatile organic compounds (VOC, boiling point range 50-240 °C) commonly produce sharp peaks when analysed by SPME-GC, while very volatile organic compounds (VVOCs, b.p. <50 °C) have early eluting peaks, which are not efficiently captured and produce deformed peaks [1]. These peaks sometimes co-eluted with other solutes or with the solvent peak and its impurities, resulting in missing chemical structure and aroma identification. In order to improve the separation and identification of VVOCs and VOCs, the effect of cryogenic trapping and pulsed injection were studied. Pulsed injection consists in to increase the pressure at the head of the capillary column at the time of injection to accelerate the material transference [2]. Cryogenic trapping decreases the temperature in the initial of the capillary column by liquefied CO2 to focusing the analytes [3].
VVOCs and VOC from Swartzia simplex flowers and lavender (Lavandula angustifolia Mill.) essential oil were extracted by SPME and desorbed at GC inlet to be analysed. All chromatograms had the chemical substances evaluated by absolute peak area, separation efficiency and quality of spectra identification under different chromatographic conditions, compared to a conventional analysis (without pulse and cryogenic trapping). For the flowers as also for the oil compounds, twice the number of chromatographic peaks was found when the cryogenic system was used. Furthermore, the sum of the absolute areas of all peaks of the flowers was 6.8x higher than conventional injection (Fig.1) and 1.4x higher for lavander oil. Besides that, different pressure values were investigated (7-55 psi) with and without cryotrap, which increase the transference of desorbed sample under a nonlinear behavior. The optimum condition was with cryogenic focusing added pulsed injection of 35 psi to be more effective than cryotrap without pulse (1.2x) and without cryotrap and pulse (1.7x). Finally, pulsed injection and cryogenic trapping provide together an improved method for VVOC and VOC analysis by SPME-GC, giving cleaner and most accurate chromatograms with higher quality mass spectra due more sample desorption into inlet system transferred to capillary tube.
Acknowledgments
CAPES, FAPERJ and CNPq.
References:
1https://www.epa.gov/indoor-air-quality-iaq/technical-overview-volatile-o....
2Novaes et al. (2015).Talanta 139, 159.
3Huang et al. (2016).J. Sep. Science 39, 2544.
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo