EVALUATION OF INTERNAL AIR QUALITY IN A METAL-MECHANICAL INDUSTRY

Vol 2, 2018 - 94842
APRESENTAÇÃO DE PAINEL
Favoritar este trabalho
Como citar esse trabalho?
Resumo

The study of air quality of indoor environments (AQI), it’s important considering that the estimate of the permanence of the population indoors reaches 90%. The main internal air pollutants are of non-biological and biological origin, giving rise to the Sick Building Syndrome. Being the mechanical metal complex, a sector representative in the economy of the Brazil, and involving the foundry and machining sectors, objects of concern regarding air quality and employee health, this study aimed to evaluate the AQI in these two sectors, quantifying the contamination by airborne bacteria, thermal comfort and CO2 concentration. The sampling of the sectors took place on a May day, in the morning and afternoon periods, following ANVISA RE 09/03. Samples were collected at 5 points in the foundry and at 8 points in the machining. For the analysis of thermal comfort and CO2 concentration, the portable CO2 analyzer was used to measure temperature, humidity and CO2 concentration. For the analysis of the airborne a set of 3 Petri dishes containing Plate Count Agar culture medium was arranged at each point on a surface at 1.50m of the floor for a period of 10 minutes using the spontaneous sedimentation technique. The analysis of the plaques was done by counting the number of colony forming units (CFU) and the Gram Stain technique was applied for morphotintorial characterization. The results of the CO2 concentration had a maximum of 620 ppm and the relative humidity presented an average of 55.7%, being within the maximum values recommended by the current norm. Temperatures in the foundry sector reached more than 30°C in the afternoon. Regarding the microbiological quality of internal air, the morning period had 599 and 1,500 UFC/m³ in the foundry and machining sectors, respectively, and the afternoon period was 367 and 463 UFC/m³ in the casting and machining, in that order. After morphotintorial analysis, it was 30.4% of the samples were of the Gram-positive bacteria, 62.5% staphylococci, 25% bacillus and 12.5% streptobacilli, and 69.6% of the Gram negative, being 71, 4% staphylococci and 28.6% bacilli. It is concluded that the machining sector showed a higher growth of microorganisms due to the characteristics of the environment, without direct exposure to heat generating sources, as in the foundry sector. There was also a predominance of Gram negative bacteria, and the factors related to thermal comfort comply with the standards established by ANVISA.

Eixo Temático
  • MICROBIOLOGIA AMBIENTAL E ANIMAL
Palavras-chave
ENVIRONMENTAL CONDITIONS
ATMOSPHERIC CONTAMINANTS
METAL-MECHANICAL INDUSTRY
AIR MICROBIOLOGY