Para citar este trabalho use um dos padrões abaixo:
Materials recycling facilities (MRFs) receive a wide diversity of solid waste due to the incorrect segregation by the population. Thereby, its air quality may be deteriorated by the presence of airborne microorganisms, such as bacteria and fungi, which are formed as bioaerosols when the waste is handled. The aim of this study was to quantify the concentration of airborne bacteria in different environments of a MRF in Londrina, Paraná. Bacterial samplings were performed during the morning and afternoon on August 14 and 17 (winter), and on October 3 and 5 (spring) at three sampling points: one inside a waste processing shed (P1), one in the office (P2), and one in the outdoor environment (P3). The settle plate method was used for the gathering of these microorganisms with an exposure time of 10 minutes at each sampling point. The concentration of bacteria (in CFU.m-3) was calculated after its growth in Petri dishes and then the Gram staining technique was applied. The results showed that the highest concentrations of bacteria were recorded during the afternoon in P3 on October 5 (2742.0 CFU.m-3) and in the morning in P1 on October 3 (1556.5 CFU.m-3). These values were, respectively, five and three times higher than 500.0 CFU.m-3, established by the Portuguese Technical Note NT-SCE-02 as the maximum recommended concentration (MRC) for bacteria. The concentration values, which ranged from 21.7 to 210.1 CFU.m-3, were lower than the MRC for every sampling point in the winter. On the other hand, the results in the spring were higher than the MRC for all samplings in P1 and P3, ranging from 559.4 to 2742.0 CFU.m-3. The Gram staining revealed that 31.6% of the isolated colonies from both winter and spring samples were Gram-negative bacteria, which are considered the ones of major health concern because there is a capsule enveloped in its outer membrane that may hinder the detection of these microorganisms by the human body. Furthermore, Gram-negative bacteria may be sources of toxins associated with adverse health effects, such as inflammatory symptoms in the respiratory system, and may also be an indication of a possible air contamination in the indoor environment. The collectors working in the waste processing shed and the outdoor environment are exposed to higher concentrations than the people working in the office. Therefore, they may be more susceptible to health problems due to air pollution caused by bacteria at the MRF studied.
Com ~200 mil publicações revisadas por pesquisadores do mundo todo, o Galoá impulsiona cientistas na descoberta de pesquisas de ponta por meio de nossa plataforma indexada.
Confira nossos produtos e como podemos ajudá-lo a dar mais alcance para sua pesquisa:
Esse proceedings é identificado por um DOI , para usar em citações ou referências bibliográficas. Atenção: este não é um DOI para o jornal e, como tal, não pode ser usado em Lattes para identificar um trabalho específico.
Verifique o link "Como citar" na página do trabalho, para ver como citar corretamente o artigo