To cite this paper use one of the standards below:
Strong scattering effects affect the in infrared vibrational absorbance spectra of samples where the morphology is changing on a scale comparable to the incident radiation. They have been interpreted as Mie scattering [1], and are particularly strong when the shape of the sample is approximately spherical. Mie scattering introduces broad oscillatory structures in the baseline, as well as peak shifts due to dispersion in the refractive index of the sample. When these features are present in the absorbance spectra, the spectral analysis is severely hampered and it is therefore desirable to remove the Mie scattering signatures from the spectra.
Since the EMSC-based Mie correction approach was introduced in 2008 [2], various methods have been proposed for removing Mie scattering from infrared absorbance spectra [3, 4]. We recently published an open source algorithm that introduced a stop criterion for the number of iterations in the iterative algorithm, and we demonstrated that the new algorithm converges fast [5]. The new algorithm proceeds until an error is minimized. The current state of the art Mie correction algorithm, the ME-EMSC code, has proven to successfully model and remove Mie scattering from infrared spectra of biological samples [5].
In this study, we apply the ME-EMSC code to infrared hyperspectral imaging data of non-biological samples. We demonstrate that strong scatter distortions in wide-field hyperspectral images of silica beads embedded in a resin matrix can be corrected by the ME-EMSC algorithm. The infrared data were acquired with a multi-beam synchrotron source coupled with an IR microscope at the IRENI beamline. The ME-EMSC algorithm takes into account the full extinction efficiency, which is considerably more computationally expensive than the approximation applied in the Mie correction algorithm of Bassan et al. [3]. Although the implementation of the full extinction efficiency increased the model complexity, we were able to decrease the computation time by optimizing the algorithm. Further, we considered practical issues for the treatment of infrared images containing large amounts of spectra, such as filtering of input spectra for the ME-EMSC optimization and a quality test of output spectra. In the present study, we suggest strategies for automated quality control of input and output spectra for the ME-EMSC algorithm.
[1] Mohlenhoff, B., Romeo, M., Diem, M., & Wood, B. R. (2005). Biophysical journal, 88(5), 3635-3640.
[2] Kohler, A., Sule-Suso, J., Sockalingum, G. D., Tobin, M., Bahrami, F., Yang, Y., ... & Martens, H. (2008). Appl. Spectrosc., 62(3), 259-266.
[3] Bassan, P., Kohler, A., Martens, H., Lee, J., Byrne, H. J., Dumas, P., ... & Gardner, P. (2010). Analyst, 135(2), 268-277.
[4] van Dijk, T., Mayerich, D., Carney, P. S., & Bhargava, R. (2013). Appl. Spectrosc., 67(5), 546-552.
[5] Solheim, J., Gunko, E., Petersen, D., Großerüschkamp, F., Gerwert, K., & Kohler, A. (2019). J. Biophotonics, e201800415.
With nearly 200,000 papers published, Galoá empowers scholars to share and discover cutting-edge research through our streamlined and accessible academic publishing platform.
Learn more about our products:
This proceedings is identified by a DOI , for use in citations or bibliographic references. Attention: this is not a DOI for the paper and as such cannot be used in Lattes to identify a particular work.
Check the link "How to cite" in the paper's page, to see how to properly cite the paper