58498

EVALUATION OF MAGNETIC FIELD APPLICATION IN MICROBIAL MIXED CULTURE FOR CHROMIUM BIORREMOTION

Favorite this paper

Effluents containing hexavalent chromium cause serious damage to living organisms if improperly disposed in the environment. This study aimed to quantify the removal of Cr (VI) and total Cr of synthetic effluent using mixed culture submitted to a magnetic field. During 7 hours and 4 minutes of magnetic field application on bioreactor operated for 9 hours at the frequency of 5 Hz, which corresponds to the flow rate of 7.07 cm3 s-1 in a system with recirculation, it was possible to observe, for initial concentration of Cr (VI) of 100 mg L-1, a removal of Cr (VI) of 100% and approximately 45.4% total Cr of the analyzed effluent, while 94% and 39%, respectively, were removed by the bioreactor without magnetic field.