Planejamento fatorial aplicado na hidrogenação eletrocatalitica do safrol mediada por ultrasom
The evaluation of all factors influencing theelectrocatalytic hydrogenation (ECH)processis laborious and time-consuming, especially if the classical one-factor-at-a-time method is adopted;in which one variable is changed while the others remain at fixed levels.An alternative and more efficient approach is the use of statistically designed methods, where the levels of all variables are simultaneously changed. This workreports afactorial design study of the safroleECH with the goal of quantifying the influence of three factors: the shape of the electrochemical cell(Rosett-type flow cell (-)/Four-way cell (+)), the ultrasound (US) mode (pulse (-)/continuos (+))and the temperature control employed(without (-)/with(+)).The controlled current preparative electrolyses were carried out with an Autolab PGSTAT101, using 30 mL undivided cell.The experiments werebased on the passage of 2Fmol-1.A cylindricalnickel bar was used as both, sacrificial anode and cathode (0.078 dm2area).A Bandelin Sonopuls ultrasonic homogenizer HD 2200 was used for the USapplication. The influenceof all factors on the conversion rate, as well as the possible interactions between them, wasestimatedfrom experiments carried out according to a full three-level factorial design. The analysis of variance of the model shows twosignificant main effects: those of the electrochemical cell designand the temperature control employed, in decreasing orderof importance. There is only one significant two-factorinteraction(p=0.005), the one involving the US mode and control of temperature. Fromthe remaining interactions, the three-factor is less significant than the other factors (p = 0.014), and will be disregarded in what follows.The main effect of the electrochemical cell designis positive (23.7%), and this factor does not present any significantinteraction with the remaining factors. This meansthat usingafour-way cell designinstead Rosett-type flow cell, will lead to 23.7% higher conversionrates,on average, at any combination of the levels of the other factors.The main effect of temperature control is negative (-12.66%).However, this factor exhibitsa positive interaction effect of about 10% with the US mode.Since thesetwo factors interact, their respective effects should be interpretedtogether.Thus, if the temperature control is applied with the pulsed US, theaverage conversion rate is lowered by 23%. The samechange with the continuous US mode, however, only diminish theconversion rate by 2%. On the other hand,when the temperature control is applied and theUS mode is changed, it causes an yield increase of 9.7%.In this context, the best conditions for the safrole ECH (89%,on average) was achieved with a four-way cell design, applying a pulsed US, and without temperature control.