Dispersão de Nanotubos de Carbono de Paredes Múltiplas em [BMIM]PF6 para Detecção Eletroquímica de Acetaminofeno

Favoritar este trabalho

Acetaminophen (N-(4-hydroxyphenyl)acetamide, ACOP) is a drug with analgesic and antipyretic action. In therapeutic doses seems to be safe and appears to have no toxic effects on human health. Meantime chronic use or large doses could cause liver disorders and inflammation of the pancreas. Thus, it is essential the development of analytical methodologies for the determination of ACOP. The aim of this work was to develop a sensor for the determination of ACOP using glassy carbon electrode (GCE) modified with the dispersion of multi-walled carbon nanotubes functionalized (fMWCNT) by acid treatment for 12 hours in the presence of 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM]PF6) and Nafion®, considering the optimized fMWCNT:[BMIM]PF6 ratio as 1:5. The electrochemical behavior of the ACOP on GCE/fMWCNT-[BMIM]PF6-Nafion® was recorded in Mcllvaine buffer pH 5 (at optimized conditions) in 1.19 × 10–5 mol L–1 ACOP and an oxidation peak at 0.530 V (vs Ag/AgCl/Cl–) and a reduction peak at 0.488 V (vs Ag/AgCl/Cl–) with separation (ΔEp) of 41.5 mV being observed, suggesting that the reversibility of ACOP was improved in comparison to an irreversible oxidation peak registered on bare GCE. The Nyquist diagrams were obtained for 1.19 × 10−3 mol L−1 ACOP in McIlvaine buffer pH 5.0 and the calculated RTC values for GCE/fMWCNT-[BMIM]PF6-Nafion® (44 Ω) were 89.4 % lower than the GCE (415.3 Ω), indicating that the film enhanced the electrical conduction pathways between the electrode surface and the supporting electrolyte. In the optimization of pulse potential frequency for ACOP on GCE/fMWCNT-[BMIM]PF6-Nafion® a characteristic of quasi-reversible redox reaction was observed and the value of apparent rate constant (ks) was calculated as 14.7 s−1  3.6 s−1. Using the square-wave voltammetry (SWV), Mcllvaine buffer pH 5 and the optimized parameters: f = 30 s−1, a = 25 mV and ΔEs = 2 mV, analytical curves were obtained for concentrations of ACOP ranging from 3.0 × 10–7 to 3.0 × 10−6 (r = 0.9933). The detection and quantification limits were obtained adopting the procedure recommended by IUPAC and the calculated values were 6.73 × 10–8 mol L−1 and 2.24 × 10–7mol L−1. The relative standard deviation (RSD) values for reproducibility (n = 5) and repeatability (n = 7) experiments were 2.34% and 2.56%, respectively, suggesting good stability and reproducibility. The ACOP determination in different commercial formulations was performed by the standard addition method and the recoveries of ACOP are 82.84 % (RSD 2.2 %), and 94.75% (RSD 3.0 %), for Tylenol® and for Tylenol®DC, respectively. These results indicated that the developed sensor was suitable for ACOP determination in real samples with high sensitivity and precision.