AERODYNAMIC EVALUATION OF INHALABLE AMPHOTERICIN B NANOCRYSTALS FOR THE TREATMENT OF PULMONARY FUNGAL INFECTIONS

Vol 4, 2026 - 345903
Abstract
Favorite this paper
How to cite this paper?
Abstract

Introduction: Pulmonary fungal infections are associated with high morbidity and mortality [2]. Amphotericin B (AmB) is a major broad-spectrum antifungal drug with a low incidence of resistance [1]; however, its intravenous administration is associated with adverse effects, such as nephrotoxicity, and requires slow infusion and hospitalization [1]. Pulmonary administration represents a promising alternative, allowing higher local drug concentrations and reduced systemic exposure [2]. Inhalable nanocrystal formulations may improve pulmonary deposition and drug efficacy [2,3].Objective: This study aimed to characterize inhalable amphotericin B nanocrystal formulations.Methodology: AmB nanosuspensions were prepared using a bead mill with Tween 80 and sodium lauryl sulfate as stabilizers. The formulations were dried by spray drying, either with or without lactose or mannitol as carriers, and physical mixtures with the carriers were also prepared. The aerodynamic profile was evaluated using a Next Generation Impactor (NGI). Results from a new batch, quantified by UV spectrophotometry and analyzed within a shorter interval after production, were compared with previous data obtained by HPLC.Results: The new batch showed higher mass recovery, with values ranging from 83.1% to 91.4%. In contrast to the previous dataset, the physical mixtures exhibited relevant aerodynamic performance, particularly the mannitol-containing formulation, which showed a fine particle fraction (FPF) of 33.38% and a fine particle dose (FPD) of 5.73 mg. The formulation obtained by spray drying with lactose also showed favorable performance, with an FPF of 30.90% and an FPD of 5.30 mg. The carrier-free formulation, which had previously exhibited the highest FPF and FPD values, did not maintain this superior performance in the new batch. Mass median aerodynamic diameter (MMAD) values ranged from 5.24 to 5.63 µm, which were higher than those previously observed for the formulations obtained by spray drying.Conclusion: The results demonstrate variability in aerodynamic performance between batches. In the new dataset, the physical mixture containing mannitol showed the best performance in terms of FPF and FPD, while the higher mass recovery allowed a more consistent evaluation of the formulations. These findings reinforce the importance of standardizing the conditions between production and analysis for the characterization of inhalable AmB nanocrystal formulations.

Share your ideas or questions with the authors!

Did you know that the greatest stimulus in scientific and cultural development is curiosity? Leave your questions or suggestions to the author!

Sign in to interact

Have a question or suggestion? Share your feedback with the authors!

Institutions
  • 1 Federal University of the State of Rio de Janeiro
  • 2 Fundação Oswaldo Cruz
Track
  • 3. Drug design and delivery
Keywords
Amphotericin B
Nanocrystals
Pulmonary drug delivery
Aerodynamic performance
Next Generation Impactor