55170

EVALUATION OF INTERFERENCES CAUSED BY METALS IN THE DETERMINATION OF PLATINUM GROUP ELEMENTS BY ICP-MS

Favorite this paper

The Platinum Group Elements (PGE, Ir, Os, Pd, Pt, Rh and Ru) have been used in many applications, such as anticancer drugs, catalyst of chemical reactions, as well as active part of automotive catalyst converters, making necessary the determination of these elements, even at low concentration. In this sense, inductively coupled plasma mass spectrometry (ICP-MS) can be used for PGE determination, due to the low limit of detection and the multielement capacity. However, the occurrence of spectral interferences due to the formation of polyatomic ions and oxides, mainly when metals are present during the determination of PGE by ICP-MS have been reported in the literature.1 Taking into account that information about these interferences are scarce in the literature and their magnitude is unknown, it is justified the development of a study regarding to interferences in PGE determination by ICP-MS caused by Cd, Hf, Lu, Mo, Ni, Pb, Ti, Yb, Y and W (from 3 to 12000 μg L-1). These metals were chosen because they are present at high concentration in the active part of automotive catalyst converters. The determination of PGE was performed in an inductively coupled plasma mass spectrometer (Elan DRC II, Perkin Elmer-SCIEX, Canada) equipped with a concentric nebulizer and a cyclonic spray chamber, monitoring the isotopes 191Ir+, 193Ir+, 189Os+, 190Os+, 192Os+, 104Pd+, 105Pd+, 106Pd+, 108Pd+, 110Pd+, 194Pt+, 195Pt+, 196Pt+, 103Rh+, 99Ru+, 101Ru+ and 102Ru+. Studies were carried out with the use of standard solutions containing 1 µg L-1 of PGE in 5% HNO3. The accuracy was evaluated through the expanded uncertainty obtained after the measurement of five replicates.2 Then, it was obtained an expanded uncertainty from 92 to 108%. Results pointed that Hf and Mo are the most critical interferents in PGE determination by ICP-MS. Hafnium interfered in the determination of Ir, Os, Pt and Rh in a range of 3 up to 12000 μg L-1, while Mo interfered in the determination of Pd, Pt and Ru in a range of 50 to 12000 μg L-1. The other metals evaluated (Cd, Lu, Ni, Pb, Yb and Y) also interfered in the PGE determination, but for a reduced number of analytes, highlighting that Y caused interference in Pd determination from 12 μg L-1. In this sense, it was observed interferences for PGE determination for different metals with different levels. It is important to mention that Ti and W did not cause interferences in PGE determination by ICP-MS.